Jutol 507 Question

Post Reply
 
User avatar
Freddy
Member
Posts: 7293
Joined: Fri. Apr. 11, 2008 2:54 pm
Location: Orrington, Maine
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Coal Size/Type: Pea size, Superior, deep mined

Post by Freddy » Sun. Sep. 06, 2009 6:42 am

I'm getting a couple of Jutol 507's ready for winter & have a question.... the top... I'm putting new rope in, no problem there, but does the top get cemented on? Or is it up to gravity to hold it on? I can see it might be handy to lift it off to clean that shelf, but I wouldn't want a puff back to blow it off.

 
User avatar
coalkirk
Member
Posts: 5185
Joined: Wed. May. 17, 2006 8:12 pm
Location: Forest Hill MD
Stoker Coal Boiler: 1981 EFM DF520 retired
Hand Fed Coal Stove: Jotul 507 on standby
Coal Size/Type: Lehigh anthracite/rice coal

Post by coalkirk » Sun. Sep. 06, 2009 9:03 am

Hi Freddy. It just sits there, no cement. If there is a "puff back" as we like to say it won't lift it off. A puff back would most likely only occur in this stove when the door is opened and it won't be nearly as dramatic as your early adventures with your boiler. :shock:


 
User avatar
Freddy
Member
Posts: 7293
Joined: Fri. Apr. 11, 2008 2:54 pm
Location: Orrington, Maine
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Coal Size/Type: Pea size, Superior, deep mined

Post by Freddy » Sun. Sep. 06, 2009 12:11 pm

Alrighty! One of them is ready to test. The other one I'm short 30" of 1/4" fibergalss rope & two fire brick. I'll pick that up next time I go to town. Thanks for the answer.

 
User avatar
the snowman
Member
Posts: 611
Joined: Mon. Sep. 29, 2008 10:38 pm
Location: upstate NY Tug Hill area
Hand Fed Coal Stove: Jotul 507
Coal Size/Type: Nut, Stove coal, Egg coal

Post by the snowman » Sun. Sep. 06, 2009 12:11 pm

Freddy:

Our stove has had a couple small explosions due to opening the door too quickly after just loading it, however, it has never lifted the top off of the stove. I have noticed after looking at a few Jotul's that on some of the stoves the top of the stove where the top sits on and seals to, has variations in height. For example the back and the front cast is at a different height than the two sides of the stove. I have looked at both the 507 and the 507b Jotul's and on every 507 the top of the stove is the same height. On every 507b I have seen, the back and the front pieces are slightly higher than the two side pieces. I don't know why, it is not like the front and back are lifted off of the base, they are just higher. I had to go look at my three stoves and both the 507b stoves are identical with the front and back cast being slighter higher than the two side cast pieces. My 507 is perfect across the top. Other than my three stoves I have looked at four 507b Jotul's and one other 507 and found the same results with them. It seems that when they were making the 507b units, they lacked in the quality control area in making sure that all the pieces fit together perfectly as they did in the older 507 units. The different height of the cast makes it harder to get the gasket on the top to seal to the top of the stove. Maybe coalkirk can add some input to this and let us know if his Jotul is like this.

the snowman.