My efm 350 has the following markings; can anyone tell me what they all mean?

There is an H stamped inside what appears to ba a clover symbol or + symbol of some sort.

Steam is 15.

Water is 30.

MIN SVRC 115 IBS HR What is this?

The code on it is EF2549.

The date is MBI 1965. Not sure what MBI is???

The guage on it is Electric Furnace Man but has U.S. Guage on the bottom with 13877.
User avatar
vwgtiman
Member
 
Posts: 84
Joined: Tue Sep 23, 2008 9:06 pm
Stove/Furnace Make: EFM-350 Losh-475


Re: efm 350 serial number and markings question

PostBy: stoker-man On: Tue Sep 29, 2009 11:28 am

One thing, you're fortunate. It's a 'coded' boiler, suitable for residential or commercial use. The H stamp adds $500 to $2000 to the cost of a new one.
User avatar
stoker-man
EFM Rep.
 
Posts: 2009
Joined: Mon Nov 19, 2007 10:33 pm
Location: Lehigh Valley, PA
Stove/Furnace Make: WCB-24 efm wood-coal boiler
Stove/Furnace Model: Hearthstone wood stove

Re: efm 350 serial number and markings question

PostBy: vwgtiman On: Wed Sep 30, 2009 11:46 am

Any idea what this is: MIN SVRC 115 IBS HR

I think the S15 is rated for 15 pounds an hour but I dont get the 115... Is there a decimal missing as in 1.15 pounds minimum an hour???
User avatar
vwgtiman
Member
 
Posts: 84
Joined: Tue Sep 23, 2008 9:06 pm
Stove/Furnace Make: EFM-350 Losh-475

Re: efm 350 serial number and markings question

PostBy: coal berner On: Wed Sep 30, 2009 2:19 pm

vwgtiman wrote:Any idea what this is: MIN SVRC 115 IBS HR

I think the S15 is rated for 15 pounds an hour but I dont get the 115... Is there a decimal missing as in 1.15 pounds minimum an hour???

On all 350 & 520 your minimum feed rate is one tooth which is 2.5 lbs a hr on a S-15 stoker the max feed rate is 6 teeth 15lbs per hr The S-20 stoker is minimum feed rate is 1 tooth 2.5lbs per hr max feed rate was 8 teeth 20lbs per hr on the early S-20 they hand a shorter gearbox arm that only aloud the gear drum with the dog paw to move that far .
same goes for the S-15 gearbox arm plus the pot was smaller in size on the early models .
The later or newer S-20 pot with the longer gearbox arm will allow the drum gear plus the dog paw move to 10 teeth
which is 25lbs per hr minimum feed rate is still 1 tooth at 2.5 lbs per hr .
What name is stamped on the boiler top lo line general machine efm cobco so on .
User avatar
coal berner
State of Pennsylvania Moderator
 
Posts: 3824
Joined: Tue Jan 09, 2007 1:44 am
Location: Pottsville PA. Schuylkill County PA. The Heart Of Anthracite Coal Country.
Stove/Furnace Make: Electric Furnace Man
Stove/Furnace Model: DF520

Re: efm 350 serial number and markings question

PostBy: stoker-man On: Wed Sep 30, 2009 4:06 pm

The 520 is rated around 400# per hr and that is the steam rating. So, I would say that 115 is the steam rating.
User avatar
stoker-man
EFM Rep.
 
Posts: 2009
Joined: Mon Nov 19, 2007 10:33 pm
Location: Lehigh Valley, PA
Stove/Furnace Make: WCB-24 efm wood-coal boiler
Stove/Furnace Model: Hearthstone wood stove

Re: efm 350 serial number and markings question

PostBy: mozz On: Wed Sep 30, 2009 5:34 pm

I thought the steam rating was 350 and 520, that's how they were named? Are marked in sq inches of radiation for steam use? The AA-130 was rated at 540?
User avatar
mozz
Member
 
Posts: 817
Joined: Mon Sep 17, 2007 5:27 pm
Location: Wayne county PA.
Stove/Furnace Make: Axeman Anderson
Stove/Furnace Model: 1982 AA-130 Steam