PostBy: StanT On: Thu Oct 15, 2009 7:17 am

where should the restrictor plate be set at on the combustion blower? Took it off to clean fan and I did not mark it, Boo Hoo

Thanks, Stant
User avatar
StanT
Member
 
Posts: 148
Joined: Fri Aug 29, 2008 5:10 am
Location: Ne Pa
Stove/Furnace Make: Leisureline
Stove/Furnace Model: econo1

Visit Leisure Line Stove

Re: econo 1

PostBy: Matthaus On: Thu Oct 15, 2009 10:51 am

Hi Stant,

The initial setting is half covered. This works very well for most most conditions.

Of course for those who like a good science project you can actually measure it. If you have a manometer you can verify the over fire draft (SB -.02" WC or so) by drilling a 3/16" hole in the stove just above the ash door and making a probe for your manometer out of 3/16" tubing, however this is not needed to properly run the stove. :)