Which baro/ hand damper configuration is correct?
Attachments
stove2.JPG
(7.51 KiB) Viewed 250 times
View: New PagePopup • Select:BBCode
[nepathumb]558[/nepathumb]
stove.JPG
(6.66 KiB) Viewed 251 times
View: New PagePopup • Select:BBCode
[nepathumb]557[/nepathumb]
dirvine96
 
Stove/Furnace Make: Hitzer 82FA

PostBy: coaledsweat On: Mon Jan 29, 2007 4:50 pm

The second one. 95% of the time.
coaledsweat
 
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

PostBy: AL-53 On: Tue Jan 30, 2007 10:17 am

If you install a hand dampner after the Baro...you take a chance of coal gas coming thru the baro when the hand dampner is closed.....If you use a hand dampner I would install it before the Baro...