Question on Keystoker Koker maintenance

Question on Keystoker Koker maintenance

PostBy: e.alleg On: Fri Feb 16, 2007 12:00 pm

I am just about to buy a Keystoker Koker direct vent to install in my basement. I have a center chimney but it is not lined and corbeled (?)(it angles up where it goes through the attic) and the chimney experts said no way to line it. My question is how long of a vent can I run horizontally and how often does it need to be cleaned out and how hard is it? I don't mind doing the work but I'm afraid of having to shut the stove down and take the vent all apart every few days will get tiring. I could run a 6" triple wall stainless chimney on the outside of the house but that will put the stove in a very undesireable spot and the added $$$$ doesn't help. Thanks for any advice.
User avatar
e.alleg
Member
 
Posts: 1389
Joined: Fri Feb 16, 2007 11:31 am
Location: western ny
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Visit Lehigh Anthracite

PostBy: coaledsweat On: Fri Feb 16, 2007 12:17 pm

You are much better off with an interior masonry chimney. Did you look into a cast in place liner? They will seal and stregthen the chimney. As long as it doesn't have any leaks (holes) you should be fine.
The longer the horizontal run, the more often you will need to clean it. I clean mine about twice per heating season, your mileage may vary.
User avatar
coaledsweat
Site Moderator
 
Posts: 6143
Joined: Fri Oct 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stove/Furnace Model: Axeman-Anderson 260M

PostBy: e.alleg On: Sat Feb 17, 2007 1:55 pm

The chimney guy said for the price of cast in place liner I could buy an outdoor boiler. I didn't look into any further, the idea is to save money not go into debt,
User avatar
e.alleg
Member
 
Posts: 1389
Joined: Fri Feb 16, 2007 11:31 am
Location: western ny
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

PostBy: Berlin On: Sat Feb 17, 2007 5:10 pm

honestly i wouldn't be too worried about using an interior unlined chimney for coal only. wood is a different story, but with coal i wouldn't hesitate provided it's not completely falling apart.
User avatar
Berlin
Site Moderator
 
Posts: 1539
Joined: Thu Feb 09, 2006 2:25 pm
Location: Buffalo/Adirondacks, NY
Stove/Furnace Make: Will-burt burning BITUMINOUS
Stove/Furnace Model: Model 77 Combustioneer

PostBy: Yanche On: Sat Feb 17, 2007 11:28 pm

I grew up in a home with an interior unlined brick chimney that had a gentle offset in it. Burned Anthracite coal for 50+ years before we switched to natural gas. Never a problem and it's still going strong. At about year 50 the exterior bricks visible above the slate roof were replaced when the rusted tin flashing was replaced. Never burned wood except to start the coal fires.

Yanche
User avatar
Yanche
Site Moderator
 
Posts: 3076
Joined: Fri Dec 23, 2005 1:45 pm
Location: Sykesville, Maryland
Stove/Furnace Make: Alternate Heating Systems, Inc
Stove/Furnace Model: S-130 Boiler burning pea coal

PostBy: Complete Heat On: Sun Feb 18, 2007 3:09 pm

You can direct vent the Koker for far less money than a liner (stainless or cast in place), or a "Class A" chimney. Ideally you would want to run it into a chimney, but I have installed Keystoker boilers and 2 Keystoker 90s with the direct vent, and they operate just fine with minimal maintenance. Try to keep your horizontal run to a minimum and install a Tee section, to allow access to the horizontal run for easy cleaning. Remember, the longer the horizontal run, the more maintenance. I would try to keep it under 3 feet.

Mike
Complete Heat
Member
 
Posts: 232
Joined: Thu Mar 09, 2006 10:46 pm
Location: Nashua, NH
Stove/Furnace Make: Axeman-Anderson
Stove/Furnace Model: AA-130/FHA

Visit Lehigh Anthracite