just purchased coal trol basic and they said i have to hook flume switch any problems you encountered with that?
wally61
 
Stove/Furnace Make: alaska
Stove/Furnace Model: channing III dv coal-trol

PostBy: bksaun On: Mon Apr 09, 2007 1:58 pm

Not sure what they mean! What stove do you have?

BK
bksaun
 
Stoker Coal Boiler: Hybrid, Gentleman Janitor GJ-6RSU/ EFM 700
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Pea Stoker/Bit, Pea or Nut Anthracite
Stove/Furnace Make: Hitzer/ EFM-Gentleman Janitor
Stove/Furnace Model: 503 Insert/ 700/GJ-62

PostBy: wally61 On: Mon Apr 09, 2007 2:05 pm

i have a alaska channing
wally61
 
Stove/Furnace Make: alaska
Stove/Furnace Model: channing III dv coal-trol

PostBy: bksaun On: Mon Apr 09, 2007 4:05 pm

So do I,I think they mean if you have a power vent. Mine go's into a Class A chimney.

The Coal Trol module has a

Plug to the convecton fan, a plug to the combustion fan,a plug to the stoker motor and a wire to the thermostat. That's it.

BK
bksaun
 
Stoker Coal Boiler: Hybrid, Gentleman Janitor GJ-6RSU/ EFM 700
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Pea Stoker/Bit, Pea or Nut Anthracite
Stove/Furnace Make: Hitzer/ EFM-Gentleman Janitor
Stove/Furnace Model: 503 Insert/ 700/GJ-62

PostBy: wally61 On: Mon Apr 09, 2007 4:16 pm

your right i have a direct vent neil said to call him when i hook up and he will walk me thru it. even gave me his cell phone to call any time great people to deal with. he was out of town thats why he did not get back to me. gonna start to get warmer so the thermo should get a little break in.do you think that the settings you have would work with my direct vent as well as yours does?
wally61
 
Stove/Furnace Make: alaska
Stove/Furnace Model: channing III dv coal-trol

Coaltrol install

PostBy: George On: Mon Apr 09, 2007 5:20 pm

Hi Wally:
I put the coal-trol on my Alaska kast consloe 3, which is the same as the Channing. I have a direct vent also. Just make sure the power for the coal-trol module run through the fume switch first. That way if the is a problem, the fume switch will shut down the stove. If you have any questions, please let me know. My settings are 2 min and 40 max. Runs great! George :)
George
 
Hot Air Coal Stoker Stove: Alaska Cast Consol 3 w/ coaltrol

PostBy: bksaun On: Mon Apr 09, 2007 5:57 pm

My settings are 5 for low fire and 38 for max. This is easy to adjust and these settings will be close or a good starting point for you.

BK