PostBy: robb On: Tue Aug 17, 2010 11:00 am

Does the Control Module of a Coal Trol set-up need to be bolted or screwed to the stove? Could it sit on the floor behind the stove?
robb
 
Stove/Furnace Make: Hitzer
Stove/Furnace Model: 608 stoker

Re: Coal Trol Control Module

PostBy: pvolcko On: Tue Aug 17, 2010 11:17 am

It can sit behind the stove, either on the floor or mounted to a board. Consider two things though:

1) We would recommend that the top panel (with the printing on it) either be facing up or have the unit mounted on a board so the unit is vertical. This is because the top plate of the module is a heat sink and should be exposed to the open air for proper cooling.

2) If installed in a basement you may want mount it on a board to get it up off the floor, where condensation or even flooding may come into play.
pvolcko