Took it up tonight

Took it up tonight

PostBy: Uglysquirrel On: Fri Dec 03, 2010 10:17 pm

Well its friday night and with the Poke cruising at 12 max and 30 fan speed all week, she was getting a little lazy. So pushed the little buttons up to 36 max, 90 fan and wow,the heat pouring off this beast is amazing and mine is"only" a 90K and I could have pushed it to 44 or so. I reaaly believe that the Poke's asset is the increased vertical surface area the air can pass by. I'm of some opinion that the base design could be modified slightly to add more fins or add surface roughness for more heat transfer though this would create a bigger delta P between the fan exits and air exhaust at the stove's top frt. This would likley have to be done during the manufacturing process and these welds to hold these fins on would likley crack and in the end it would not be worth it cause that is why a leisure line is a leisure line....


Now I'm thinkin about doing a youtube video !!!
Uglysquirrel
 
Stove/Furnace Model: Pocono

Re: Took it up tonight

PostBy: WNY On: Sat Dec 04, 2010 8:11 am

My Hyfire is still only running 1 burner (90K), but the FR was about 65+ last night and not quite keeping up, I will be lighting the second burner, since it's supposed to get down into the Teens and 20's the rest of the week....
WNY
 
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Stove/Furnace Make: Keystoker, LL & CoalTrol
Stove/Furnace Model: 90K, Hyfire I, VF3000 Soon

Re: Took it up tonight

PostBy: coalnewbie On: Sat Dec 04, 2010 8:35 am

Ugly,

I know the feeling. During the autumn I felt that the Poco was not really putting out but it sure settles in as the air gets colder and denser. I keep about 5000ft heated (more or less) and now I have to push things a bit now and WOW. UP to 32 max so far and so far keeping up and that is a miracle for me. The bigger box is more efficient at putting out the heat (not a surprise). A permanent Dwyer install is making me more efficient. I'll be watching u tube. I am now wondering about an external coil and making steam for humidity. Opinions?? Also thinking about DHW but there is just the two of us. So say a hyfire with DHW coil inside must make WAY more hot water than I would need. Don't like the posts about hycoil rusting. Perhaps a cute little stove dedicated to the job would be better.
coalnewbie
 
Hot Air Coal Stoker Stove: LL AnthraKing 110K, Pocono110K,KStokr 90K, DVC
Hand Fed Coal Stove: Hitzer 50-93, Jotul 507
Baseburners & Antiques: Red Cross Invader 2
Coal Size/Type: Rice, Chestnut
Other Heating: Heating Oil CH, Toyotomi OM 22

Visit Leisure Line Stove

Visit Leisure Line Stove