coal not burning completely in Van Wert furnace

coal not burning completely in Van Wert furnace

PostBy: chico72 On: Sun Jan 16, 2011 8:01 pm

I have a Van Wert Model 600 coal furnace. I am burning hard coal. The air adjustment is open all the way but I am getting unburnt coal in the ashes. Anyone out there have any ideas for a solution? Thanks
chico72
New Member
 
Posts: 1
Joined: Sun Jan 16, 2011 7:18 pm
Stove/Furnace Make: Van Wert
Stove/Furnace Model: 600


Re: coal not burning completely in Van Wert furnace

PostBy: Scottscoaled On: Sun Jan 16, 2011 8:12 pm

Did it just start doing that or did it start when you got the new load of coal? For starters I would let the fire burn out and then vacumn out the grates and take a mirror and look to see if the grates are cracked or pluged. Van Werts burn buckwheat. Burning rice clogs up the grates. You can also look in thru the ash door and on the bottom of the pot there is a small cleanout door. Maybe she's full of fines and she can't breath :)
Scottscoaled
Member
 
Posts: 1494
Joined: Tue Jan 08, 2008 10:51 pm
Location: Malta N.Y.
Stove/Furnace Make: Efm, ,
Stove/Furnace Model: 520x3 350 700

Re: coal not burning completely in Van Wert furnace

PostBy: WNY On: Sun Jan 16, 2011 8:22 pm

I guess it depends on how much unburnt, most stoves will have a certain amount of unburnt coal. usually a few small pieces.
But, yes, you may need to clean out the under the grates, holes, etc... good.