MK II top door

MK II top door

PostBy: chet On: Mon Oct 15, 2007 7:36 pm

Well I am done curing the paint on my MK II, put a wood fire in it and it did the job, I noticed while I was burning it in my driveway, that the top door has a slight gap up on the left corner I can see the glow of the fire slightly for about 2 inches, should I let it be. the gap is very little maybe the thickness of the paper from a matchpack.

Chet
chet
 

PostBy: Wood'nCoal On: Mon Oct 15, 2007 8:08 pm

I had a similar condition on my MK 1, I tightened the door by bending the door latch striker (the part attached to the stove) a very small amount. It's right when you grab the handle and pull/push, the door should be tight against the stove, but not so tight that it's difficult to latch.

Also, check the door gasket to see if any sections are missing or damaged. gasket material is available and it's easy to change.
Wood'nCoal
 
Stoker Coal Boiler: 1959 EFM 350
Hand Fed Coal Stove: Harman Magnafire Mark I
Coal Size/Type: Rice and Chestnut
Other Heating: Fisher Fireplace Insert

Proper end where

PostBy: chet On: Wed Oct 17, 2007 6:03 am

Just for the records, On my MK II top flue vent, I take it the stove pipe crimped end goes in the stove. I know this is the way for a wood stove so the creosote does not leak back down.

thanks
Chet
chet
 

Visit Hitzer Stoves

PostBy: coal berner On: Wed Oct 17, 2007 1:13 pm

You are correct crimped end goes inside of stove flue or you can flip the

pipe around and try outside of flue with coal either way will work have fun
coal berner
 
Stoker Coal Boiler: 1986 Electric Furnace Man 520 DF
Stove/Furnace Make: Electric Furnace Man
Stove/Furnace Model: DF520

PostBy: coaledsweat On: Wed Oct 17, 2007 1:27 pm

And don't use galvanized stovepipe with coal, black only.
coaledsweat
 
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Visit Hitzer Stoves