manometer install

Re: manometer install

PostBy: dave brode On: Sun Oct 24, 2010 6:55 pm

Here is my install.

I used common 3/16" brake line. Note the small 90* pipe thread to inverted flare fitting that allows be used. They come in straight too. Any good parts house.

I welded a 1/8" coupler onto the flue, but Dwyer included nuts with 1/8" pipe thread to attach the supplied barbed fitting to a flue pipe [with a washer]. Those nuts would work on the pipe thread end of the fittings that I used too.

I put a piece of hose on the high side nipple too, to prevent dirt from getting in.

Dave
Attachments
Oct24^03.JPG
(143.64 KiB) Viewed 212 times
View: New PagePopup • Select:BBCode
[nepathumb]22805[/nepathumb]
Oct24^14.JPG
(168.08 KiB) Viewed 130 times
View: New PagePopup • Select:BBCode
[nepathumb]22806[/nepathumb]
Oct24^11.JPG
(98.58 KiB) Viewed 144 times
View: New PagePopup • Select:BBCode
[nepathumb]22807[/nepathumb]
User avatar
dave brode
Member
 
Posts: 416
Joined: Fri Jan 15, 2010 6:47 pm
Location: Frostburg, Maryland [western]
Stove/Furnace Make: Keystoker Kaa-2


Re: manometer install

PostBy: sperry On: Sun Jan 23, 2011 7:08 pm

Here's my install. Thanks for all the great install info :!:
Attachments
efm012011 003.jpg
(144.5 KiB) Viewed 110 times
View: New PagePopup • Select:BBCode
[nepathumb]25186[/nepathumb]
efm012011 016.jpg
(115.07 KiB) Viewed 78 times
View: New PagePopup • Select:BBCode
[nepathumb]25187[/nepathumb]
User avatar
sperry
Member
 
Posts: 45
Joined: Fri Nov 05, 2010 10:55 pm
Location: SWVT
Stove/Furnace Make: efm/alaska
Stove/Furnace Model: 520/fireplace insert

Re: manometer install

PostBy: dandy On: Sat Mar 19, 2011 6:01 pm

Just did an install on my Ka-6 of a manometer using a magnhelic guage instead. THe guage seems to work just as good as the manometer, but I am not getting the reading of a dwyer 25. Still have minor issuse to address but since this is saturday afternoon and the parts stores are closed will get to them next week. just need a fireproof washer to install on stove pipe connection then use furnace cement on fitting to tie everything together. So far have under 20 dollars invested and I'm very happy with how it seems to perform....
dandy
Member
 
Posts: 31
Joined: Wed Jul 16, 2008 6:12 pm
Location: northern maine
Stove/Furnace Make: keystoker
Stove/Furnace Model: ka-6 dual fuel

Re: manometer install

PostBy: dh1200s On: Tue Nov 15, 2011 7:02 am

I liked MURDOC1 post on this subject http://nepacrossroads.com/about21625.html and went that direction with some small dia brass tubing I had on hand sleeving it down for using silicone tubing easily found at the hobby shop.

The two manometers I received from a discount vendor were delivered with oil but no tubing to connect from the adapter to the manometer..........Dick
Attachments
PB130032.JPG
(74.89 KiB) Viewed 32 times
View: New PagePopup • Select:BBCode
[nepathumb]30889[/nepathumb]
PB130040.JPG
(29.28 KiB) Viewed 52 times
View: New PagePopup • Select:BBCode
[nepathumb]30890[/nepathumb]
PB130037.JPG
(37.1 KiB) Viewed 37 times
View: New PagePopup • Select:BBCode
[nepathumb]30891[/nepathumb]
Mamometer fitting 4.JPG
(61.95 KiB) Viewed 56 times
View: New PagePopup • Select:BBCode
[nepathumb]30892[/nepathumb]
Mamometer fitting 3.JPG
(51.25 KiB) Viewed 30 times
View: New PagePopup • Select:BBCode
[nepathumb]30893[/nepathumb]
Mamometer fitting 5.JPG
(50.45 KiB) Viewed 52 times
View: New PagePopup • Select:BBCode
[nepathumb]30894[/nepathumb]
dh1200s
Member
 
Posts: 56
Joined: Sat Jul 18, 2009 1:12 pm
Location: Honey Brook, Pa.
Stove/Furnace Make: WL110/165 Boiler
Stove/Furnace Model: HS-Tarm 202, Harman TLC 2K

Re: manometer install

PostBy: Boots On: Sun Feb 26, 2012 9:59 am

I got my dwyer and got it installed. its been about 35*f during the day here and im getting .02 In of wc with boiler at low fire with 230*f stack temp. and about .03 to .04 in of wc at high fire with 500*f + stack temp. burnham recommends .05 in of wc. Im assuming that when the temp drops some more that my draft will go up but also im assuming that running .03-.04 inches will be ok. I mean my chimney drafts what it drafts, there is not much that can be done to change that. There is a little bit of ash in the pipe between the baro and the boiler but not much. and on the opposite side of the baro the pipe is clean. I cleaned the sealing surface of my chimney clean out door and sealed it with silicone to stop any potential leaks. My home is pretty tight so i cracked a basement window slightly to help improve the draft as well. What else can i do? at some point today i will climb up on the roof and look down the chimney to see if all is clear, which i expect it will be.
Boots
Member
 
Posts: 109
Joined: Thu Nov 10, 2011 5:38 pm
Location: Central PA
Stove/Furnace Make: Burnham
Stove/Furnace Model: SFB-101 hand fired boiler.

Re: manometer install

PostBy: Wiz On: Tue Sep 18, 2012 7:54 pm

I see that most use the dwyer oil fill manometer, why not the digital ones.

http://www.dwyer-inst.com/Product/Press ... s/Digital/
User avatar
Wiz
Member
 
Posts: 445
Joined: Sun Nov 27, 2011 9:45 pm
Location: Tannersville Pa
Stove/Furnace Make: KeyStoker
Stove/Furnace Model: Ka-6 Boiler

Re: manometer install

PostBy: lsayre On: Tue Sep 18, 2012 7:58 pm

Wiz wrote:I see that most use the dwyer oil fill manometer, why not the digital ones.

http://www.dwyer-inst.com/Product/Press ... s/Digital/


The oil filled manos only cost about $34. And calibration is as simple as leveling them and having them filled with the proper amount of the proper oil. How do you calibrate one of those $200+ digital manometers, and how long does it stay calibrated?
User avatar
lsayre
Member
 
Posts: 3959
Joined: Wed Nov 23, 2005 10:17 pm
Location: N/E Ohio, near Wadsworth
Stove/Furnace Make: AHS S130 Coal Gun

Re: manometer install

PostBy: Wiz On: Tue Sep 18, 2012 8:03 pm

lsayre wrote:
Wiz wrote:I see that most use the dwyer oil fill manometer, why not the digital ones.

http://www.dwyer-inst.com/Product/Press ... s/Digital/


The oil filled manos only cost about $34. And calibration is as simple as leveling them and having them filled with the proper amount of the proper oil. How do you calibrate one of those $200+ digital manometers, and how long does it stay calibrated?


I found them for $36.89 on eb@y
User avatar
Wiz
Member
 
Posts: 445
Joined: Sun Nov 27, 2011 9:45 pm
Location: Tannersville Pa
Stove/Furnace Make: KeyStoker
Stove/Furnace Model: Ka-6 Boiler

Re: manometer install

PostBy: lsayre On: Tue Sep 18, 2012 8:09 pm

Try Cole Parmer. Less expensive, and way less shipping cost to boot.
User avatar
lsayre
Member
 
Posts: 3959
Joined: Wed Nov 23, 2005 10:17 pm
Location: N/E Ohio, near Wadsworth
Stove/Furnace Make: AHS S130 Coal Gun

Re: manometer install

PostBy: 2001Sierra On: Tue Sep 18, 2012 9:41 pm

"dave brode" Here is my install.

I used common 3/16" brake line. Note the small 90* pipe thread to inverted flare fitting that allows be used. They come in straight too. Any good parts house.

What a nice setup! What kind of wax do you use on your equipment :roll:
User avatar
2001Sierra
State of New York Moderator
 
Posts: 780
Joined: Wed May 20, 2009 8:09 am
Location: Wynantskill NY, 10 miles from Albany
Stove/Furnace Make: Keystoker with Coal-Trol
Stove/Furnace Model: Keystoker 90 Chimney Vent

Re: manometer install

PostBy: Wiz On: Sun Sep 30, 2012 12:29 pm

Order a dwyer 25 mano, should be here by weds. I'll see how far off my draft is ;)
User avatar
Wiz
Member
 
Posts: 445
Joined: Sun Nov 27, 2011 9:45 pm
Location: Tannersville Pa
Stove/Furnace Make: KeyStoker
Stove/Furnace Model: Ka-6 Boiler

Re: manometer install

PostBy: Poconoeagle On: Wed Oct 03, 2012 9:52 pm

Hey Wiz, check out,"Got a manometer-now what" thread......

8-)
User avatar
Poconoeagle
State of Pennsylvania Moderator
 
Posts: 6777
Joined: Sat Nov 08, 2008 8:26 pm
Location: Tobyhanna PA
Stove/Furnace Make: Buckwalter & Co. , EFM520
Stove/Furnace Model: No. 28 Glenwood 1880, Alaska

Re: manometer install

PostBy: Wiz On: Thu Oct 04, 2012 5:51 pm

Poconoeagle wrote:Hey Wiz, check out,"Got a manometer-now what" thread......

8-)


Yup read that one, good info... Heading out to workshop, my manometer is here.
User avatar
Wiz
Member
 
Posts: 445
Joined: Sun Nov 27, 2011 9:45 pm
Location: Tannersville Pa
Stove/Furnace Make: KeyStoker
Stove/Furnace Model: Ka-6 Boiler

Re: manometer install

PostBy: Wiz On: Fri Oct 05, 2012 9:11 pm

Keystoker Ka-6.... Recommends draft setting at idle -.01 and draft settings at demand -.02 Checking of draft is to be check at pre drilled hole in door.

Image

Image


Image
User avatar
Wiz
Member
 
Posts: 445
Joined: Sun Nov 27, 2011 9:45 pm
Location: Tannersville Pa
Stove/Furnace Make: KeyStoker
Stove/Furnace Model: Ka-6 Boiler

Re: manometer install

PostBy: SMITTY On: Fri Oct 05, 2012 9:16 pm

Minus? On my setup that indicates NO draft ... actually a backflow at that stage .... hence the red because that's not good .... :gee:
User avatar
SMITTY
Member
 
Posts: 8953
Joined: Sun Dec 11, 2005 1:43 pm
Location: West-Central Mass
Stove/Furnace Make: Harman
Stove/Furnace Model: Mark III