New (to Me) Axeman 260

 
User avatar
tsb
Member
Posts: 2616
Joined: Wed. Jul. 30, 2008 8:38 pm
Location: Douglassville, Pa
Stoker Coal Boiler: Binford 2000
Hot Air Coal Stoker Stove: LL Pioneer top vent
Hand Fed Coal Stove: Saey Hanover II
Baseburners & Antiques: Grander Golden Oak , Glenwood # 6
Coal Size/Type: All of them

Post by tsb » Wed. Jan. 04, 2012 4:36 pm

No DHW yet ? Your missing the best part.


 
User avatar
Townsend
Member
Posts: 573
Joined: Tue. Nov. 21, 2006 7:38 pm
Location: Connecticut
Hand Fed Coal Stove: Hitzer 50-93 & Harman Mark I
Coal Size/Type: Pea / Nut

Post by Townsend » Wed. Jan. 04, 2012 5:39 pm

tsb wrote:No DHW yet ? Your missing the best part.
Soon, very soon!!!

 
User avatar
Townsend
Member
Posts: 573
Joined: Tue. Nov. 21, 2006 7:38 pm
Location: Connecticut
Hand Fed Coal Stove: Hitzer 50-93 & Harman Mark I
Coal Size/Type: Pea / Nut

Post by Townsend » Wed. Jan. 04, 2012 5:45 pm

Hope you guys don't mind pics, cause I sure like taking 'em of that steam boiler.

Tidied up a bit in the boiler room. Got a little oiling station, finally organized my tools a bit and kicked my feet up a little while at my reading/thinking station.

Attachments

IMG_5034.JPG

Oiling station

.JPG | 139.3KB | IMG_5034.JPG
IMG_5054.JPG

Kicking back

.JPG | 130.4KB | IMG_5054.JPG
IMG_5063.JPG

sitting area

.JPG | 199.6KB | IMG_5063.JPG
IMG_5055.JPG

Required reading in the boiler room!

.JPG | 203KB | IMG_5055.JPG

 
titleist1
Member
Posts: 5226
Joined: Wed. Nov. 14, 2007 4:06 pm

Post by titleist1 » Wed. Jan. 04, 2012 5:53 pm

soooo which one of those boiler pics will be your Christmas card photo for next year?!?! :idea:

 
User avatar
SteveZee
Member
Posts: 2512
Joined: Wed. May. 11, 2011 10:45 am
Location: Downeast , Maine
Hand Fed Coal Stove: Glenwood Modern Oak 116 & Glenwood 208 C Range

Post by SteveZee » Wed. Jan. 04, 2012 6:05 pm

titleist1 wrote:soooo which one of those boiler pics will be your Christmas card photo for next year?!?! :idea:
Ha,ha,ha..Yep I copied a couple myself to use as "primers" for when my time comes. Awesome looking train.

 
User avatar
firewoodman
Member
Posts: 152
Joined: Sat. Dec. 19, 2009 9:10 pm
Location: Carbondale, Pa.

Post by firewoodman » Wed. Jan. 04, 2012 11:09 pm

Just wait till you hook up your DHW....Is it possible to have a 360 degree smile??? Unlimited HOT showers with no worries of running out of hot water...Wait till your utility bills show up...then youll actually SEE the difference. Welcome to the axeman family...and nice job on the install. I see youve got some really shiny pennies there with that pipeing...I was worth every cent...every drop of sweat....busted knuckles.... Did you get the comment "youre changing over to coal????" wait till one of then complains about their bills...then you can let out a big laugh!!!!!

 
User avatar
Townsend
Member
Posts: 573
Joined: Tue. Nov. 21, 2006 7:38 pm
Location: Connecticut
Hand Fed Coal Stove: Hitzer 50-93 & Harman Mark I
Coal Size/Type: Pea / Nut

Post by Townsend » Thu. Jan. 05, 2012 10:34 pm

I think my Honeywell S400B timer is not working. I have two pins in it set all the way in. There is power to it and is wired per AA schematic yet it does not run. I will need it for summer DHW. Does anyone have instructions on how to operate it?

Firewodman, yes, I got that comment. Look who's laughing now. Already two friends expressed real interest in getting coal stoker boilers.


 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Thu. Jan. 05, 2012 10:48 pm

Townsend wrote:I think my Honeywell S400B timer is not working. I have two pins in it set all the way in. There is power to it and is wired per AA schematic yet it does not run. I will need it for summer DHW. Does anyone have instructions on how to operate it?
Steve,

When you say it doesn't run...do you mean primarily, the clock motor doesn't advance? or the load isn't being switched?

 
User avatar
Townsend
Member
Posts: 573
Joined: Tue. Nov. 21, 2006 7:38 pm
Location: Connecticut
Hand Fed Coal Stove: Hitzer 50-93 & Harman Mark I
Coal Size/Type: Pea / Nut

Post by Townsend » Thu. Jan. 05, 2012 11:22 pm

Mc, the clock does not advance nor does it switch or cycle. I think its because the clock dial does not advance. I took the pins out of the dial, and to be honest, I'm having a difficult time getting them back into the dial.

I'm at a loss how to set this thing. The inner case under the dial refers to different color pins. I've seen others with more pins. What gives with these timers? Also, I've heard that if the timer malfunctions while in cycle that the boiler can stay in a fire mode. How can this be if it is wired to aquastat, presuretrol etc?

By the way, on the last pic, isn't the boiler room a nice place to be? Do you think the uninsulated 4 inch drop down header might have anything to do with this???? :)

Attachments

IMG_5067.JPG
.JPG | 180.5KB | IMG_5067.JPG
IMG_5070.JPG
.JPG | 156.3KB | IMG_5070.JPG
IMG_5071.JPG
.JPG | 119.3KB | IMG_5071.JPG
IMG_5074.JPG
.JPG | 138.9KB | IMG_5074.JPG

 
User avatar
coaledsweat
Site Moderator
Posts: 13763
Joined: Fri. Oct. 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Post by coaledsweat » Fri. Jan. 06, 2012 7:57 am

The two black wires coming from the rear are the timer motor. Connect them to an extension cord and plug it in. If the timer runs it may be wired improperly. If it doesn't, it's junk.

 
User avatar
coaledsweat
Site Moderator
Posts: 13763
Joined: Fri. Oct. 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Post by coaledsweat » Fri. Jan. 06, 2012 9:15 am

Townsend wrote:How can this be if it is wired to aquastat, presuretrol etc?
The timer is wired to over ride the other controls, it powers the motor directly according to AA's drawings in both hot water and steam applications.
I have 4 pins you can have, my timer died a long time ago, I doubt it will need them. :)

 
User avatar
coaledsweat
Site Moderator
Posts: 13763
Joined: Fri. Oct. 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Post by coaledsweat » Fri. Jan. 06, 2012 10:40 am

coaledsweat wrote:I have 4 pins you can have
:mad: LOL, If I can figure out how they come out! :D

 
User avatar
Townsend
Member
Posts: 573
Joined: Tue. Nov. 21, 2006 7:38 pm
Location: Connecticut
Hand Fed Coal Stove: Hitzer 50-93 & Harman Mark I
Coal Size/Type: Pea / Nut

Post by Townsend » Fri. Jan. 06, 2012 4:14 pm

Ok, I'm starting to figure this out. The unit seems to function in that I can get it to make and break. The white and black arms on the left of the photo below are the actuating arms I believe. The white arm when pulled upward seems to click into a set position. When it is then flipped back downwards the boiler fires. For the black arm it seems it also sets in the upward position but when it flips back down it shuts off the boiler. I was able to get the pins back on the dial and I can see where one of the pin's tabs that protrude from the back of the dial when mounted will trip the white arm and the other pin's tab is located to trip the black arm due to their location from the center of axis. It seems like more is needed because if the dial only spins in one direction, lets say counter clockwise the pin tabs will only flip the arms one way. Hence, does the dial change directions after it flips an arm? For instance, the white arm needs to be set by bringing it to the up position. It then needs to be snapped back to the lower position whereupon it fires the boiler. Likewise, the black pin needs two movements as well, up and down, to stop the boiler.

I have yet to see the little white gear rotate so perhaps I am not seeing all there is with this switch / timer. It is difficult with no instructions to follow.

I will keep trying but can any one who uses this switch please explain how they are set and operate.

Attachments

IMG_5071.JPG
.JPG | 119.3KB | IMG_5071.JPG

 
User avatar
coaledsweat
Site Moderator
Posts: 13763
Joined: Fri. Oct. 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Post by coaledsweat » Fri. Jan. 06, 2012 4:31 pm

Townsend wrote:I have yet to see the little white gear rotate so perhaps I am not seeing all there is with this switch / timer. It is difficult with no instructions to follow.
If the little white gear won't turn when powered up, the clock motor is gone. There is nothing wrong with the switch itself, the timer just doesn't run. The pins set an on and off cycle. One will trip it on and the next in line will trip it off. Where you put the pins will determine what your start and stop time will be. Some people set two pins, some four. Generally the start stop cycles are in the two/four minute range.

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Fri. Jan. 06, 2012 11:15 pm

Here was one fellow's fix:

Honeywell S400B Timer


Post Reply

Return to “Stoker Coal Boilers Using Anthracite (Hydronic & Steam)”