Aquastats, Boiler Stage Relays, Etc.

Post Reply
 
User avatar
wilder11354
Member
Posts: 1221
Joined: Sat. Jan. 29, 2011 10:48 pm
Location: Montrose, Pa.
Hand Fed Coal Boiler: Harman SF260 Boiler
Hand Fed Coal Stove: Hitzer 50-93
Coal Size/Type: nut or pea, anthracite
Other Heating: crown oil boiler, backup.if needed

Post by wilder11354 » Mon. Nov. 21, 2011 9:22 pm

I am finally getting a grip on the controls that come with a SF260 harman. The Johnson Controls A350 (aquastat relay) is used to control the aux air blower for burn chamber when theres a heat loss(load demand) in water temp incoal boiler. The S350(stage) relay is the boiler Dump controller. The Y350 is the 24V transformer and bridge that interconnects the other 2 relays together and powers them.

Just trying to figure out how to stage the oil boiler, if possible off the A350, whithout interferring with blower operation. If possible, if not will need another aquastat for staging oil boiler off coal boilers temps for turning on circulator from oil boiler. Hmmmmmmm.


 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Mon. Nov. 21, 2011 10:21 pm

Been discussed previously...Dual Boiler Plumbing and Wiring.