By: niceheat On: Thu Feb 07, 2013 12:29 am
I have a Legend outdoor coal furnace that I purchased around 9 years ago. It sat in the yard not hooked up until last winter. When i bought it I was told any handiman could hook it up. Unfortuneatly I am not a handyman so I had a hard time finding someone to do it. There was a big problem hooking it up as there was no manual or instructions that came with it, so this has been a big learning curve in figureing how this machine works, and have been learning the hard way of what not to do. There is very little help from dealers and I am not impressed with the lack of knowledge about the system from the people selling them. After several breakdowns of different kinds this winter and last winter, I have come to know this machine a lot better. There is a problem with these blowing smoke down the auger tube which is warm and when it goes into the hopper it condenses and builds up ice around the auger. This happened this winter and broke the auger in two. The dealer did not come up with any fix for this so we came up with our own which is working well now. I have this posted on this site. I am still having bridging problems which i think is only going to get solved by putting the hopper inside a heated building. I will use some loops inside the building to keep some warnth in there and it should be ok. My boyfriend who worked on this several times for me this winter says the stoker is a piece of junk and that it is put together pretty scabby. He says the gear box is not a good design. The boiler on the other hand I am happy with. There has been no problems with that at all. The stoker is made by Legend as well. I looked into other models before I bought this one and was considering a Coalman. I went and saw one that was close to where i live and the guy was very happy with it and his son was getting one too. He had an overhead hopper bottom bin and was all automated. He said there wasnt much work to maintain it at all. Mine on the other hand seems to need more maintenance than I was told it would. Maybe once I have all the bugs out of the setup, it wont be so much of a baby. I have lines going to my house to heat the 1500 sq ft floor and it is heating the whole house very well which is 3,000 sq ft. I also have lines going to a 16 wide mobile home with a radiator in the furnace. It is not hooked up completly the way it should be yet but it is helping out with heat. It needs more to heat to run more efficiently though. I had planned on heating a barn as well so I got the 14" which is 340,000 btu's. I feel it is a very effecient system, when it is running you see no smoke, only a little when it is idling. If I had more to heat it would be even more efficient. I know other people that have a Legend and they are happy with it and have run theirs for about 10 years.