Axeman Owners: How Many "Clicks"?
- Townsend
- Member
- Posts: 573
- Joined: Tue. Nov. 21, 2006 7:38 pm
- Location: Connecticut
- Hand Fed Coal Stove: Hitzer 50-93 & Harman Mark I
- Coal Size/Type: Pea / Nut
I was wondering what others have their ashing arm set to for driving the ash pan gear. How many clicks do you have it set for? Have you experimented with adjustments at all? I had mine set at 2 clicks but recently set it to 3. Hard to really tell with this change in weather.
- AA130FIREMAN
- Member
- Posts: 1954
- Joined: Sat. Feb. 28, 2009 4:13 pm
3 , occasionally it will only do 2, when it's 64 years old, it's hard sometimes to count, shaft may not be 100% true, and bushings not as tight as a drum. What will become of me once I hit that age Once you find a happy spot with the adjustments, in my case I keep them the same. No outfires this season and real good results (once an hour for one minute on the timer). I will say the uae harmony coal has alot to do with it. Very little ash,better drafting with less ash, and I don't need to clean the flyash from the stove pipe every 6 weeks like I did the first year.
- Freddy
- Member
- Posts: 7301
- Joined: Fri. Apr. 11, 2008 2:54 pm
- Location: Orrington, Maine
- Stoker Coal Boiler: Axeman Anderson 130 (pea)
- Coal Size/Type: Pea size, Superior, deep mined
I keep mine at 2 clicks. It might run a bit longer during extremely cold weather, but it delivers the coal slower so the fire stays higher.
- steamup
- Member
- Posts: 1209
- Joined: Fri. Oct. 03, 2008 12:13 pm
- Location: Napoli, NY
- Stoker Coal Boiler: Axeman-Anderson AA-130, Keystoker K-6
- Hand Fed Coal Boiler: HS Tarm 502 Wood/Coal/Oil
- Coal Size/Type: pea, buck, rice
Mine is set at 2 clicks. One click under light load would probably be ok. With a heavy load or high ash coal, you may need 3 clicks. Check on how much your ashing solenoid cycles. If it cycles occasionally under load, it is probably ok. If it cycles alot you may be trying to ash too much. If it doesn't cycle, you may be ashing too little. (assuming your anthrastat is calibrated properly).
- LsFarm
- Member
- Posts: 7383
- Joined: Sun. Nov. 20, 2005 8:02 pm
- Location: Michigan
- Stoker Coal Boiler: Axeman Anderson 260
- Hand Fed Coal Boiler: Self-built 'Big Bertha' SS Boiler
- Baseburners & Antiques: Keystone 11, Art Garland
3-1/2 clicks.. on the pull side of the notched wheel, when the grate is being pulled out from under the fire, and the clinkers are being jammed against the lower lip of the firepot, the linkage rebounds some, resulting in only 3 clicks.. on the push side it's usually 4 clicks.
My solenoid will eventually cycle, if the boiler's run is long enough. but it ashes every time the boiler fires up.
I do tend to get a lot of clinkers, I almost never have an ashpan without 4-6 fist or double-fist sized clinkers. Sometimes a phonebook sized one !!
I think the clinkers that get caught on the firepot lip, sometimes 'roll' around in the firepot as the grate tries to push them out of the fire.. this 'rolling' I think is one cause of the occassional piece or two of unburnt coal in an otherwise ashpan of nothing but powder and a few large clinkers. I have no way to prove this, but I just can't figure out how a bunch of pieces of perfect, shiney black coal make their way into the ashpan.. and avoid the fire completley..
Greg L.
My solenoid will eventually cycle, if the boiler's run is long enough. but it ashes every time the boiler fires up.
I do tend to get a lot of clinkers, I almost never have an ashpan without 4-6 fist or double-fist sized clinkers. Sometimes a phonebook sized one !!
I think the clinkers that get caught on the firepot lip, sometimes 'roll' around in the firepot as the grate tries to push them out of the fire.. this 'rolling' I think is one cause of the occassional piece or two of unburnt coal in an otherwise ashpan of nothing but powder and a few large clinkers. I have no way to prove this, but I just can't figure out how a bunch of pieces of perfect, shiney black coal make their way into the ashpan.. and avoid the fire completley..
Greg L.
- mozz
- Member
- Posts: 1363
- Joined: Mon. Sep. 17, 2007 5:27 pm
- Location: Wayne county PA.
- Stoker Coal Boiler: Axeman Anderson 1982 AA-130 Steam
This sums it up perfectly.
steamup wrote:Check on how much your ashing solenoid cycles. If it cycles occasionally under load, it is probably ok. If it cycles alot you may be trying to ash too much. If it doesn't cycle, you may be ashing too little. (assuming your anthrastat is calibrated properly).
- whistlenut
- Member
- Posts: 3548
- Joined: Sat. Mar. 17, 2007 6:29 pm
- Location: Central NH, Concord area
- Stoker Coal Boiler: AA130's,260's, AHS130&260's,EFM900,GJ & V-Wert
- Hand Fed Coal Boiler: Franks,Itasca 415,Jensen, NYer 130,Van Wert
- Hot Air Coal Stoker Furnace: Alaska, EFM, Keystoker, Yellow Flame
- Hot Air Coal Stoker Stove: Alaska, Keystoker-2,Leisure Line
- Hand Fed Coal Stove: Alaska, Gibraltar, Keystone,Vc Vigilant 2
- Hand Fed Coal Furnace: Ford, Jensen, NYer, Van Wert,
- Baseburners & Antiques: Glenwoods
- Coal Size/Type: Barley, Buck, Rice ,Nut, Stove
- Other Heating: Oil HWBB
3 clicks for me with the current coal I'm burning. Very typical this part of the winter. That is in 260's, 2 clicks most of the time in 130's. Damned...that 'steamup' doesn't miss anything. Jon is a very clever fellow.....nice guy too! I think he needs a Losch to play with next......perhaps a GJ.
- McGiever
- Member
- Posts: 10130
- Joined: Sun. May. 02, 2010 11:26 pm
- Location: Junction of PA-OH-WV
- Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
- Hand Fed Coal Boiler: BUCKET A DAY water heater
- Hand Fed Coal Stove: Warm Morning 414A
- Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
- Other Heating: Ground Source Heat Pump and some Solar
1 click... occasionally get 2 clicks in the cycle
burning UAE buckwheat with a light load.
Hold Fire Timer skips running because boiler is sitting above upper high limit alot. Never an out fire though.
Here is a bit of Axeman Trivia for all...It takes 42 clicks to do one complete cycle of rolling grate travel out and back...2 inches each way.
(At least on my 1959 130M it is.)
burning UAE buckwheat with a light load.
Hold Fire Timer skips running because boiler is sitting above upper high limit alot. Never an out fire though.
Here is a bit of Axeman Trivia for all...It takes 42 clicks to do one complete cycle of rolling grate travel out and back...2 inches each way.
(At least on my 1959 130M it is.)
- steamup
- Member
- Posts: 1209
- Joined: Fri. Oct. 03, 2008 12:13 pm
- Location: Napoli, NY
- Stoker Coal Boiler: Axeman-Anderson AA-130, Keystoker K-6
- Hand Fed Coal Boiler: HS Tarm 502 Wood/Coal/Oil
- Coal Size/Type: pea, buck, rice
Ok, Ok - Too much information - Who in the heck sits there and counts how many "clicks" it takes to travel the grate. I guess curiosity got the cat on that one.McGiever wrote:1 click... occasionally get 2 clicks in the cycle
burning UAE buckwheat with a light load.
Hold Fire Timer skips running because boiler is sitting above upper high limit alot. Never an out fire though.
Here is a bit of Axeman Trivia for all...It takes 42 clicks to do one complete cycle of rolling grate travel out and back...2 inches each way.
(At least on my 1959 130M it is.)
- McGiever
- Member
- Posts: 10130
- Joined: Sun. May. 02, 2010 11:26 pm
- Location: Junction of PA-OH-WV
- Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
- Hand Fed Coal Boiler: BUCKET A DAY water heater
- Hand Fed Coal Stove: Warm Morning 414A
- Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
- Other Heating: Ground Source Heat Pump and some Solar
Sometimes a guy just has too much time on his hands.steamup wrote:Ok, Ok - Too much information - Who in the heck sits there and counts how many "clicks" it takes to travel the grate. I guess curiosity got the cat on that one.McGiever wrote:1 click... occasionally get 2 clicks in the cycle
burning UAE buckwheat with a light load.
Hold Fire Timer skips running because boiler is sitting above upper high limit alot. Never an out fire though.
Here is a bit of Axeman Trivia for all...It takes 42 clicks to do one complete cycle of rolling grate travel out and back...2 inches each way.
(At least on my 1959 130M it is.)
- McGiever
- Member
- Posts: 10130
- Joined: Sun. May. 02, 2010 11:26 pm
- Location: Junction of PA-OH-WV
- Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
- Hand Fed Coal Boiler: BUCKET A DAY water heater
- Hand Fed Coal Stove: Warm Morning 414A
- Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
- Other Heating: Ground Source Heat Pump and some Solar
Actually, I didn't sit there and count all the "clicks" while firing...I was lubricating the cam followers before it was put into service here, and still had the back plate removed and no coal loaded in burn pot...it was pretty simple to manually ratchet quickly and keep count while starting and finishing at one end of the grate's travel.McGiever wrote:Sometimes a guy just has too much time on his hands.steamup wrote: Ok, Ok - Too much information - Who in the heck sits there and counts how many "clicks" it takes to travel the grate. I guess curiosity got the cat on that one.