PID Controller for Operating Limit Control?

 
Bob
Member
Posts: 304
Joined: Sun. Mar. 18, 2007 11:28 am
Location: Schuylkill County
Stoker Coal Boiler: AHS 130
Coal Size/Type: Pea/Anthracite

Post by Bob » Thu. Nov. 29, 2007 2:25 pm

U235a4 wrote:ok I think I may have figured a few things out but let me go thru the running order with how I think your units running.

your unit runs untill it reaches the operating limit of 170 on the L4006a unit and if your using a timer the high limit of 190 won't let the unit run until it falls below that. if the temp goes above 205 the circulator won't run and your dead in the water till the unit cools
The L4006A is the operating limit and has a fixed differential. If the sensed coal boiler water temperature drops below the operating set point the draft blower comes on and runs until the L4006A is satisfied. The high limit is a backup to the operating limit and if the high limit is triggered it cuts power to the operating limit control to prevent operation of the draft blower. If the circulator override is triggered (sensed temperature of the coal boiler water greater than 205) then the circulator for the B coil in the air handler in the out building, as well as the fan in the air handler are turned on and remain on until the circulator override sensed temperature drops below the set point.

I have no timer.


 
U235a4
Member
Posts: 320
Joined: Mon. Oct. 29, 2007 8:26 pm
Location: South Central PA

Post by U235a4 » Thu. Nov. 29, 2007 4:37 pm

Bob, Now that I found the switch to my crystal ball and see why you have your unit wired the way you do. All I can say is that if you don't have excessive draft which you said you don't you'll have to look at your ashing and maybe set it to a cooler setting so it doesn't have as much fresh coal to make a hot coal bed in the unit. now to all the AA AHS people out there if you don't know if you do ignore this but when you cool your ashing or slow it down whether it be anthrastat or timer you also so down pickup on the unit, but you don't have the big over ride problems. When you make your ash hotter or speed up ashing you’ll be putting more fresh coal in the unit you speed heat pickup, but you also with have bigger overrides.