It's Happened!!! and Only Two Seasons in...

 
User avatar
Lightning
Site Moderator
Posts: 14669
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sun. Dec. 16, 2012 3:53 pm

SO, how about running stove pipe up to the chimney flue liner and sealing it there with fiberglass insulation?
Or have you tried that already? Unless you have some serious stack effect going on in the house (air leakage thru the roof) I don't see why this wouldn't work...

 
CapeCoaler
Member
Posts: 6515
Joined: Sun. Feb. 10, 2008 3:48 pm
Location: Cape Cod, MA
Stoker Coal Boiler: want AA130
Hand Fed Coal Stove: DS Machine BS#4, Harman MKII, Hitzer 503,...
Coal Size/Type: Pea/Nut/Stove

Post by CapeCoaler » Wed. Dec. 19, 2012 11:01 pm

I go with Berlin taller is better...
I have a short exterior metalbestos chimney...
I was 3 feet over the peak...
Added 2 feet and now it drafts very well...

 
User avatar
I'm On Fire
Member
Posts: 3918
Joined: Thu. Jun. 10, 2010 9:34 am
Location: Vernon, New Jersey
Hand Fed Coal Stove: DS Machines DS-1600 Hot Air Circulator

Post by I'm On Fire » Thu. Dec. 20, 2012 10:12 am

CapeCoaler wrote:I go with Berlin taller is better...
I have a short exterior metalbestos chimney...
I was 3 feet over the peak...
Added 2 feet and now it drafts very well...
I added two (2) feet to the chimney this past summer. It didn't help.


 
KLook
Member
Posts: 5791
Joined: Sun. Feb. 17, 2008 1:08 pm
Location: Harrison, Tenn
Other Heating: Wishing it was cold enough for coal here....not really

Post by KLook » Thu. Dec. 20, 2012 10:46 am

I think it is the exterior chimney at fault. It stays to cool and the air is not rising and creating good draft. If it was only the length of the chimney, my metalbestos one would not work at all. Because its insulated, it maintains a temp. difference. Mine is only 6 inch and drafts super.
Is your unit such that you could burn some wood or paper or cardboard? Get some heat into the chimney and check the draft. I think the mass of the chimney is such that it is just sucking up the heat before it can establish a draft out the top.

Just my .02 worth

Kevin

 
franco b
Site Moderator
Posts: 11417
Joined: Wed. Nov. 05, 2008 5:11 pm
Location: Kent CT
Hand Fed Coal Stove: V ermont Castings 2310, Franco Belge 262
Baseburners & Antiques: Glenwood Modern Oak 114
Coal Size/Type: nut and pea

Post by franco b » Thu. Dec. 20, 2012 10:59 am

Lightning wrote:Right, He tried taller :D I think exhausting gases from a vehicle are a bit different than the natural draft of a chimney fellas, help me out here :lol:
Keeping more heat in the chimney has got to make a difference and a smaller outlet at the top should do that. You could try that with a piece of sheet metal with a 6 inch hole, or use a chimney pot that will also restrict the opening. Too much cold air can sink into that big opening.

 
User avatar
Rob R.
Site Moderator
Posts: 18003
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Thu. Dec. 20, 2012 11:08 am

My brother is heating his house with a Hitzer stove connect to an exterior masonry chimney (8" round flue)...it drafts fine even on 45 degree days. The chimney is 42 blocks high, a few feet over the peak. I'm sure it would draft better if the chimney was inside the house, but my point is that even an exterior chimney should provide acceptable performance if it is tall enough.

My EFM is connected to a huge brick chimney that goes up through our living room. I think the chimney is 32' high, just over the peak, and the first 12' is inside the house. It provides sufficient draft even in July.


 
KLook
Member
Posts: 5791
Joined: Sun. Feb. 17, 2008 1:08 pm
Location: Harrison, Tenn
Other Heating: Wishing it was cold enough for coal here....not really

Post by KLook » Thu. Dec. 20, 2012 11:24 am

exterior masonry chimney (8" round flue).
That 8 inch round is far better then this rock heavy mass outside chimney. I am not sure from reading through the post if it is lined. If it is not or if it is with 12x12, there is a large amount of air space surrounded with very cold stone etc. I think he almost has to have a draft inducer to get good draft with the lack of a high temp exhaust. Wood fires were so inefficient they worked fine, other then the creosote. Where do you stop going up to get a draft with cool exhaust? How about make up air? Has this been covered in past posts?

Kevin

 
User avatar
Lightning
Site Moderator
Posts: 14669
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Thu. Dec. 20, 2012 8:51 pm

franco b wrote:Keeping more heat in the chimney has got to make a difference and a smaller outlet at the top should do that. You could try that with a piece of sheet metal with a 6 inch hole, or use a chimney pot that will also restrict the opening. Too much cold air can sink into that big opening.
If anything, its worth a try... Just do it when your home to monitor the draft and give the chimney time to adapt to a smaller opening at the top. I know it seems to not make sense, but if cold air is sinking in because the opening is too big, it may help.. 8-)

 
User avatar
I'm On Fire
Member
Posts: 3918
Joined: Thu. Jun. 10, 2010 9:34 am
Location: Vernon, New Jersey
Hand Fed Coal Stove: DS Machines DS-1600 Hot Air Circulator

Post by I'm On Fire » Sat. Dec. 22, 2012 5:42 pm

I do run a draft inducer. The chimney is lined with 9x13 terracotta tile. The chimney is outside on the north end of the house. I have thought about framing the chimney out and insulating it then siding it. I'm not sure if it can be done though. I think the chimney is just too big. Inside siameter is 8x12. This is the first season I'm using the chimney itself as last season I had a 16' 316Ti liner in it.

Post Reply