PostBy: Rusty4cyl On: Mon Jun 18, 2012 6:35 pm

I have a Honeywell L8024A triple aqua stat that stopped working. What triple aqua stat can I replace this with. Your help is greatly appreciated. Thanks Rusty
Rusty4cyl
New Member
 
Posts: 4
Joined: Sun Jun 17, 2012 11:02 pm
Stove/Furnace Make: EFM
Stove/Furnace Model: 520


Re: Triple aquastat

PostBy: Rob R. On: Mon Jun 18, 2012 8:31 pm

Honeywell's L7224U is the direct replacement for the L8124A. The L7224U is digital, and you will need the instructions to get it programmed. New old stock L8124A aquastats are often available on eBay if you like the traditional interface.

By the way, what went wrong with your existing aquastat?
User avatar
Rob R.
Member
 
Posts: 5030
Joined: Fri Dec 28, 2007 5:26 pm
Location: Chazy, NY
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: Triple aquastat

PostBy: Rusty4cyl On: Mon Jun 18, 2012 8:45 pm

Rob R I have an L8024A You said an L8124A Is this aqua stat still a replacement for an L8024A. My furnace keeps going out. When the water temp goes down, it doesn't run the stoker to keep water hot, only runs on timer, so it doesn't run enough to keep fire going. Thanks Rusty
Rusty4cyl
New Member
 
Posts: 4
Joined: Sun Jun 17, 2012 11:02 pm
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: Triple aquastat

PostBy: Rob R. On: Mon Jun 18, 2012 9:03 pm

:oops:

I missed the different digit in the model number. Based on what I found online, the L8024A preceded the L8124A...you should be able to replace yours with a L8124A or L7224U.
User avatar
Rob R.
Member
 
Posts: 5030
Joined: Fri Dec 28, 2007 5:26 pm
Location: Chazy, NY
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: Triple aquastat

PostBy: Rusty4cyl On: Mon Jun 18, 2012 10:18 pm

Thanks Rob R for your help. I appreciated it Thanks Rusty
Rusty4cyl
New Member
 
Posts: 4
Joined: Sun Jun 17, 2012 11:02 pm
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: Triple aquastat

PostBy: creek44 On: Wed Jun 20, 2012 9:42 am

I installed a Hydrostat Model 3150 manufactured by the Hydrolevel Company when I refurbished my EFM 520.
I am very pleased with its quality and operation. I liked the fact that I could mount it on the wall away from the boiler with a 20ft. extension from the thermowell. The digital readout can be plainly seen from a distance. Its operation has been flawless.
creek44
Member
 
Posts: 20
Joined: Tue Aug 23, 2011 12:20 pm
Location: Eastern Ohio
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: Triple aquastat

PostBy: whistlenut On: Wed Jun 20, 2012 10:09 am

I've had excellent luck with the 3150 as well. Have been using them since 2008 when I first noticed the literature.
I also like the remote placement of the unit....AND with their well, it also has a low water cutoff for only $12.00+/-more. A NO-Brainer!
We use them on all hydronic units, oil, coal or wood..... :idea:

Pex Supply and Patriot Supply .....as well as many supply houses have them in stock...about $140.00 DO NOT forget to order the LWCO insert AND the extended remote cable.
User avatar
whistlenut
State of New Hampshire Moderator
 
Posts: 2742
Joined: Sat Mar 17, 2007 6:29 pm
Location: Central NH, Concord area
Stove/Furnace Make: AA130's/AA260's,AHS 130's-260
Stove/Furnace Model: GJ 600,EFM DF520-900 VWert 600

Re: Triple aquastat

PostBy: Rob R. On: Wed Jun 20, 2012 10:30 am

creek44 wrote:I installed a Hydrostat Model 3150 manufactured by the Hydrolevel Company when I refurbished my EFM 520.


I need to do a better job gathering my thoughts before I post. First I misread the model number in the original post, and then I forget to mention that I have a Hydrostat 3150 on my EFM. :roll: Good thing others are watching.

The only issue I had with the 3150 was lack of clearance between the aquastat well and the newly installed extended coil mount. That issue is probably unique to my boiler because it was retrofitted with the new coil mount. I didn't know they offered a remote mounting kit at the time, so I mounted the control on the boiler jacket and had to run a ground wire to the theromwell to make the LWCO function work properly.

whistlenut wrote:Pex Supply and Patriot Supply ....


I got mine from Patriot Supply. Great price and I had it in two days.
User avatar
Rob R.
Member
 
Posts: 5030
Joined: Fri Dec 28, 2007 5:26 pm
Location: Chazy, NY
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: Triple aquastat

PostBy: Rusty4cyl On: Sat Jul 14, 2012 10:23 am

Thanks for your help guy's. I bought a 3150. What do you set your setting's at. Do you turn off the low limit setting. I had mine set at 180 -10 high and 160- 10 low. It shuts off at 160, but till it gets cool enough to start again, it goes out. Thanks Rusty
Rusty4cyl
New Member
 
Posts: 4
Joined: Sun Jun 17, 2012 11:02 pm
Stove/Furnace Make: EFM
Stove/Furnace Model: 520