Hybrid Boiler Project

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Sun. Aug. 12, 2012 9:44 am

Rushing to get my boiler installed before winter, Its aan EFM 700 with a Jentleman Janitor stoker, we have tested our local Bituminous and it burns well, should be able to burn Anthracite or Bit which is difficult to do.

Building is 16'x16'
DSCF0463.jpg

6 inches of concrete

.JPG | 182.1KB | DSCF0463.jpg
Bk
DSCF0464.jpg
.JPG | 143.3KB | DSCF0464.jpg
DSCF0466.jpg
.JPG | 128.6KB | DSCF0466.jpg
DSCF0468.jpg

1/2 inch pex in floor.

.JPG | 228.2KB | DSCF0468.jpg
Last edited by bksaun on Sun. Aug. 12, 2012 11:44 am, edited 1 time in total.


 
User avatar
Rob R.
Site Moderator
Posts: 17979
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Sun. Aug. 12, 2012 9:52 am

Beautiful background in the photos. Please keep us updated as the project moves along. Pictures of the boiler and stoker would be eeeeexcellent.

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Sun. Aug. 12, 2012 9:57 am

Have not picked it up yet, rushing to get ready.

Bk

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Sun. Aug. 12, 2012 10:06 am

Frame up going well if the wether cooperates.
DSCF0566.jpg
.JPG | 168.2KB | DSCF0566.jpg
DSCF0567.jpg
.JPG | 177.8KB | DSCF0567.jpg
DSCF0568.jpg
.JPG | 174.2KB | DSCF0568.jpg
DSCF0572.jpg

Insulation added, metal next

.JPG | 136.6KB | DSCF0572.jpg

 
User avatar
EarthWindandFire
Member
Posts: 1594
Joined: Sat. Dec. 18, 2010 12:02 pm
Location: Connecticut
Hot Air Coal Stoker Furnace: Leisure Line Lil' Heater.
Other Heating: Oil Furnace and Kerosene Heaters.

Post by EarthWindandFire » Sun. Aug. 12, 2012 10:39 am

Hi Bill,

Nice project!

What are the dimensions of your boiler building?

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Sun. Aug. 12, 2012 11:43 am

16'x16'.

Bk

 
User avatar
Dennis
Member
Posts: 1082
Joined: Sun. Oct. 30, 2011 5:44 pm
Location: Pottstown,Pa
Hand Fed Coal Boiler: AHS/WOC55-multi-fuel/wood,oil,coal
Coal Size/Type: Anthracite/stove size

Post by Dennis » Sun. Aug. 12, 2012 1:46 pm

will the coal bin be inside,keep up the good work, winter will be here sooner than you think


 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Mon. Aug. 13, 2012 8:53 pm

Yes, inside with a loading door for a front end loader on the left side of the building.

Bk

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Sun. Aug. 19, 2012 9:23 am

Progress....
DSCF0582.jpg

Metal almost done

.JPG | 130.9KB | DSCF0582.jpg
DSCF0580.jpg

Coal loading door to the left of the window.

.JPG | 119.4KB | DSCF0580.jpg

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Mon. Sep. 17, 2012 6:41 pm

Moving right along, chimney done, 1" pex al pex insulated with pipe insulation, inside sch 30 pvc and 3 inches of closed cell foam around that buried at least 24" deep, (frost line is 18" here).
DSCF0605.jpg

3 inches minimum of closed cell foam

.JPG | 233.3KB | DSCF0605.jpg
DSCF0596.jpg

sch 30 pvc with pex inside

.JPG | 231.4KB | DSCF0596.jpg
Moving right along with the project.
DSCF0584.jpg
.JPG | 133KB | DSCF0584.jpg
DSCF0585.jpg
.JPG | 98.6KB | DSCF0585.jpg
DSCF0589.jpg

Not much room for insulation

.JPG | 165.9KB | DSCF0589.jpg
DSCF0590.jpg
.JPG | 98.3KB | DSCF0590.jpg
DSCF0595.jpg
.JPG | 137.6KB | DSCF0595.jpg

Attachments

DSCF0604.jpg
.JPG | 160.7KB | DSCF0604.jpg

 
User avatar
Dennis
Member
Posts: 1082
Joined: Sun. Oct. 30, 2011 5:44 pm
Location: Pottstown,Pa
Hand Fed Coal Boiler: AHS/WOC55-multi-fuel/wood,oil,coal
Coal Size/Type: Anthracite/stove size

Post by Dennis » Mon. Sep. 17, 2012 6:55 pm

It's coming along good. Will you be running insulated or uninsulated pex inside the conduit.So,will the next set of pics. be the stoker.

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Mon. Sep. 17, 2012 7:05 pm

The pex is insulated inside the pvc pipe, thats about as good as I can do short of pulling a vacume on the PVC.

I will be making a trip to PA to pick up the stoker and boiler soon.

 
User avatar
Rob R.
Site Moderator
Posts: 17979
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Mon. Sep. 17, 2012 7:18 pm

Looking good! Great piece of property you have there...I really enjoy the pictures.

 
User avatar
CoalHeat
Member
Posts: 8862
Joined: Sat. Feb. 10, 2007 9:48 pm
Location: Stillwater, New Jersey
Stoker Coal Boiler: 1959 EFM 350
Hand Fed Coal Stove: Harman Magnafire Mark I
Baseburners & Antiques: Sears Signal Oak 15 & Andes Kitchen Range
Coal Size/Type: Rice and Chestnut
Other Heating: Fisher Fireplace Insert

Post by CoalHeat » Mon. Sep. 17, 2012 10:25 pm

Nice work! Looking forward to more photos as you progress.

 
User avatar
SMITTY
Member
Posts: 12520
Joined: Sun. Dec. 11, 2005 12:43 pm
Location: West-Central Mass
Stoker Coal Boiler: EFM 520 Highboy
Coal Size/Type: Rice / Blaschak anthracite
Other Heating: Oil fired Burnham boiler

Post by SMITTY » Mon. Sep. 17, 2012 10:47 pm

MAN is that one GORGEOUS slice of American soil right there!!! I would die for that view! :up: Doesn't get any better than that right there!

KY is where I'll probably move if I ever get out of this God-forsaken bastion alive ....

That building is MINT. Nice work! 100x more livable than my house is! :lol: