Auger bushing change

Auger bushing change

PostBy: Catwood On: Fri Oct 26, 2012 9:31 pm

Anybody with suggestions on changing the auger bushings in EFM 350 , any ideas greatly appreciated. John
Catwood
 
Stove/Furnace Make: EFM
Stove/Furnace Model: 350

Re: Auger bushing change

PostBy: Rob R. On: Fri Oct 26, 2012 9:46 pm

A piece of 1/2" black iron pipe should allow you to drive the bushing out of the pot housing. Put the new one in the same way. As long as you have the stoker on the bench, I could completely go through it and replace the auger (unless it was recently replaced). Check the fit & operation of the fines cleanout plate, the wedges might need to be adjusted.
Rob R.
 
Stoker Coal Boiler: EFM DF520
Hand Fed Coal Stove: Hitzer 50-93
Coal Size/Type: Lehigh Rice
Other Heating: Dad's 1953 EFM Highboy