PostBy: roadking On: Mon Nov 19, 2012 10:54 pm

Keystoker Bay window older model with manual controls, grate removed furnace clean but fire is taking longer to burn in 1 area pushing alittle unburnt coal off. Any suggestions check out picture
Attachments
Bay window fire.jpg
(212.12 KiB) Viewed 38 times
View: New PagePopup • Select:BBCode
[nepathumb]38006[/nepathumb]
roadking
 
Stove/Furnace Make: Keystokers/New Yorker
Stove/Furnace Model: K4,Baywindow

Re: Fire not burning straight accross grate

PostBy: Wiz On: Tue Nov 20, 2012 6:36 am

After cleaning are you sure grate is install correctly. On Ka-6 it'll cause uneven burn issues
Wiz
 
Stoker Coal Boiler: Keystoker Ka 6
Coal Size/Type: Casey Junk Coal :(

Re: Fire not burning straight accross grate

PostBy: Freddy On: Tue Nov 20, 2012 7:03 am

I'd start at square one.... disassemble, clean, check all holes, check under grate for ash build up, check & replace gaskets as needed. Even check stove pipe & draft. Don't forget to check the blower itself. Are the blades clean & tight to the shaft?
Freddy
 
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Hot Air Coal Stoker Stove: Reading piece o' junk in the barn (rice)
Coal Size/Type: Pea size, Superior, deep mined

Visit Lehigh Anthracite

Re: Fire not burning straight accross grate

PostBy: McGiever On: Tue Nov 20, 2012 11:49 am

All fires are representative of the air pattern being applied.

Correct the air pattern and all will be good. Some good tips already given. :)
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hot Air Coal Stoker Stove: HARMAN MAGNUM
Hand Fed Coal Stove: RADIANT HOME AIR BLAST
Baseburners & Antiques: OUR GLENWOOD 111 BASEBURNER "1908"
Coal Size/Type: PEA / ANTHRACITE, NUT-STOVE / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek

Visit Lehigh Anthracite