Manual Pipe Dampers .. How, Why, When

 
rberq
Member
Posts: 6442
Joined: Mon. Apr. 16, 2007 9:34 pm
Location: Central Maine
Hand Fed Coal Stove: DS Machine 1300 with hopper
Coal Size/Type: Blaschak Anthracite Nut
Other Heating: Oil hot water radiators (fuel oil); propane

Post by rberq » Sat. Oct. 26, 2013 12:15 pm

.sorry, double post


 
User avatar
Lightning
Site Moderator
Posts: 14652
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sat. Oct. 26, 2013 1:06 pm

Putting the manual between the barometric and the stove won't influence how far open the baro door opens.

Putting the manual after the barometric will, but is not recommended due to possible CO leaking. I would only try it if you have a manometer installed. I just started a topic on just that same scenario.

 
rberq
Member
Posts: 6442
Joined: Mon. Apr. 16, 2007 9:34 pm
Location: Central Maine
Hand Fed Coal Stove: DS Machine 1300 with hopper
Coal Size/Type: Blaschak Anthracite Nut
Other Heating: Oil hot water radiators (fuel oil); propane

Post by rberq » Sat. Oct. 26, 2013 3:06 pm

Lightning wrote:Putting the manual between the barometric and the stove won't influence how far open the baro door opens.
Why not? My thought was, slowing the passage of hot flue gas into the chimney should result in less hot air in the chimney, therefore less draft, therefore less need for the baro door to open.

 
User avatar
Lightning
Site Moderator
Posts: 14652
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sat. Oct. 26, 2013 4:00 pm

rberq wrote:
Lightning wrote:Putting the manual between the barometric and the stove won't influence how far open the baro door opens.
Why not? My thought was, slowing the passage of hot flue gas into the chimney should result in less hot air in the chimney, therefore less draft, therefore less need for the baro door to open.
Yes sir, That makes sense, but that's not what I've observed to happen. I've tried it. As long as the chimney is warm, it continues to pull the same.

 
User avatar
Chuck_Steak
Member
Posts: 386
Joined: Wed. Jan. 06, 2010 9:03 pm
Location: New Hampster
Coal Size/Type: mostly nut, sometimes stove, Santa brand

Post by Chuck_Steak » Sun. Nov. 03, 2013 8:23 pm

rberq wrote:...So this year I added a manual damper below the baro... Closed or open, it seems to make no difference whatsoever. Coal consumptions is about the same as before. ..manual damper is fully closed, and the baro is STILL open almost half way.
The baro's operation is a function of pressure, not volume...
You could have the same pressure whether you have a 1" pipe, or 6" pipe.
It's the volume that differs.

Dan

 
KingCoal
Member
Posts: 4833
Joined: Wed. Apr. 03, 2013 1:24 pm
Location: Elkhart county, IN.
Hand Fed Coal Stove: 1 comforter stove works all iron coal box stove, seventies.
Baseburners & Antiques: 2014 DTS C17 Base Burner, GW #6, GW 113 formerly Sir Williams, maybe others at Pauliewog’s I’ve forgotten about
Coal Size/Type: Nut Anth.
Other Heating: none

Post by KingCoal » Tue. Nov. 19, 2013 8:25 am

Finally, I have my crazy "industrial leave vac." chimney under control.

the current series of controls is

stove

Dwyer pick up line

MPD

Baro.

MPD

wall thimble

the lower MPD keeps heat in the stove, the upper MPD brings the draft down to where the Baro. can work as intended to prevent over draft during higher winds but not produce a constant draw of room air out the chimney 24/7.

last night I had 6-9 mph winds and could not induce the stove to go positive with both MPD's closed while the Baro. and intake where held wide open. the mano. reading was -.005.

i'm satisfied for now.

 
scottybk
Member
Posts: 52
Joined: Sat. Nov. 12, 2011 10:09 pm

Post by scottybk » Sat. Nov. 23, 2013 8:52 pm

Manual pipe damper = instant death by monoxide, turn your house into a lethal gas chamber within minutes, should be banned by local/state/federal law and anyone caught using one in a home with children is prosecuted for child abuse, need to get them all off the hardware store shelves IMMEDIATELY and hire gestapo to go door to door and confiscate all that remain in private hands and melt them down in a blast forge.

Baro Damper= best invention since the polio vacccine, can heat 12,000 sq foot house all winter in Alaska with 1/4 ton of nut, sometimes even get heat with NO fire in stove just by gazing at baro damper, not having one is akin to going 125 mph down a mountain road w/ no seatbelt, if you don't have one get one yesterday folks ALL PRAISE THE BARO DAMPER HALLELUJAH AMEN!


 
User avatar
freetown fred
Member
Posts: 30292
Joined: Thu. Dec. 31, 2009 12:33 pm
Location: Freetown,NY 13803
Hand Fed Coal Stove: HITZER 50-93
Coal Size/Type: BLASCHAK Nut

Post by freetown fred » Sat. Nov. 23, 2013 9:23 pm

Just in case you were serious-------Speakin of gestapo--you do understand that your little rant about MPD's is unadulterated bullshit. I don't know where you get your info from, but it's validity is lacking muchly--don't be spoutin crap that apparently you have little knowledge about, there's enough BS floatin around out in the world in this day & age. PS--just for the record--lighten up on what ever drugs you're abusing :drool: :eek2:

 
User avatar
Lightning
Site Moderator
Posts: 14652
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sun. Nov. 24, 2013 7:48 am

Hey Fred, did you swap out the manual damper for a barometric yet?

 
User avatar
freetown fred
Member
Posts: 30292
Joined: Thu. Dec. 31, 2009 12:33 pm
Location: Freetown,NY 13803
Hand Fed Coal Stove: HITZER 50-93
Coal Size/Type: BLASCHAK Nut

Post by freetown fred » Sun. Nov. 24, 2013 7:50 am

They have their place my friend--my hand-fired is not one of them--BUT--I am still alive contraire to some current mis-information :clap: toothy

 
User avatar
Lightning
Site Moderator
Posts: 14652
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sun. Nov. 24, 2013 7:57 am

Yeah I know lol was just kicking yer goat hahaha

I dunno, seems like yer living on the edge. Manual pipe damper, no man-o-meter. I think you better swap out that manual for a barometric partner :lol:

 
User avatar
lsayre
Member
Posts: 21781
Joined: Wed. Nov. 23, 2005 9:17 pm
Location: Ohio
Stoker Coal Boiler: AHS S130 Coal Gun
Coal Size/Type: Lehigh Anthracite Pea
Other Heating: Resistance Boiler (13.5 KW), ComfortMax 75

Post by lsayre » Sun. Nov. 24, 2013 8:10 am

Lightning wrote:Yeah I know lol was just kicking yer goat hahaha

I dunno, seems like yer living on the edge. Manual pipe damper, no man-o-meter. I think you better swap out that manual for a barometric partner :lol:
Fred: Really, no manometer?

 
User avatar
Rob R.
Site Moderator
Posts: 17965
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Sun. Nov. 24, 2013 8:14 am

lsayre wrote:
Lightning wrote:Yeah I know lol was just kicking yer goat hahaha

I dunno, seems like yer living on the edge. Manual pipe damper, no man-o-meter. I think you better swap out that manual for a barometric partner :lol:
Fred: Really, no manometer?
I don't have one either. The baro is WIDE OPEN and making a sucking noise...I think that means I have enough draft.

 
User avatar
Lightning
Site Moderator
Posts: 14652
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sun. Nov. 24, 2013 8:15 am

Fred likes to keep things simple, Larry :D

 
User avatar
freetown fred
Member
Posts: 30292
Joined: Thu. Dec. 31, 2009 12:33 pm
Location: Freetown,NY 13803
Hand Fed Coal Stove: HITZER 50-93
Coal Size/Type: BLASCHAK Nut

Post by freetown fred » Sun. Nov. 24, 2013 8:17 am

I know, I know. I'm so antiquated, I'm still holdin a candle back by my exhaust & as long as the flame keeps getting sucked up, I'm good--WARNING, WARNING---" DO NOT TRY THIS AT HOME" ;)