Yanche wrote:U235a4 wrote:if you have anymore questions let me know because I've been thru the mill with the honeywell units out there.
Do you have experience with the Honeywell AQ475A Aquatrol Outdoor Temperature Compensator for Boilers? How well might it work on an AHS S130 for year round use with a indirect hot water heater?
Question for you, what controls do you have on the boiler now? And you answer your question yes it will but I would like to know more about your install aka # of zones, valves or pumps if you have a good picture just send it my way. just to let you know here are "SOME" of the differences of the units and prices
AQ475A1004 $154.04
• Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature.
• Selectable Warm Weather Shut Down (WWSD) at 70 F (21 C) to prevent summer boiler operation.
• Domestic Hot Water (DHW) priority.
• Replaceable circulator relay common to other
• Supply and outdoor sensors included.
• Automatic boiler operating differential.
• Automatic system circulator exercising. Long life DC relay drive control technology.
• Troubleshooting LEDs.
• Push-to-test button.
• Full size screw terminals.
• Functional replacement for Honeywell T475A Outdoor Reset.
• Controller and W964F Aquatrol (on-off mode).
• Post Purge 10sec
AQ2504B2 $219.83 - MUST USE AQ1000TN2 Thermo
• Factory configured for control of up to four zones plus domestic hot water.
• Expandable up to 16 zones with expansion zoning modules (sold separately).
• Single stage boiler control synchronized to zone-of-greatest-demand.
• Reduced boiler short-cycling.
• Integral Domestic Hot Water control.
• Installer selectable DHW Priority.
• Installer selectable DHW Priority Override
• Post Purge 30sec
AQ2514B2 $431.39 - MUST USE AQ1000TN2 Thermo
• Factory configured for control of up to four zones plus domestic hot water.
• Expandable up to 16 zones with expansion zoning modules (sold separately).
• Menu-based 3-line backlit LCD display.
• Separate user and installer configuration modes.
• Outdoor reset of boiler temperature.
• Optional Load reset of boiler temperature based on thermostat demand.
• Warm weather shut down. Installer program backup.
• Centralized 7-day setback program with warm-up boost.
• Single stage boiler control synchronized to zone-of-greatest-demand.
• Reduced boiler short-cycling. Integral Domestic Hot Water control.
• Installer selectable DHW Priority.
• Installer selectable DHW Priority Override.
• Freeze protection.
• Boiler shock protection.
• Burner short cycle protection.
• Boiler heat post purge. Self-test mode.
• Post Purge 0-30mins
AQ1000TN2 $70.62
2-WIRE NON-PROGRAMMABLE COMMUNICATING THERMOSTAT for use with AQ 250/251 controls