PostBy: naomi On: Wed Dec 12, 2007 6:43 am

Is plastic plumbing the way of the future?
naomi
 

Re: plastic plumbing

PostBy: traderfjp On: Wed Dec 12, 2007 8:09 am

PVC has been around for a very long time. Are u talking about hotwater applications?
traderfjp
 
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing 3

Re: plastic plumbing

PostBy: bksaun On: Wed Dec 12, 2007 9:58 am

IMO it is ok for drain lines, but for anything with presure on it, copper is the way to go...PERIOD!

They sell pvc gold and clain it works, but we have seen some of these fail, remember when water is flowing under presure it causes vibration and when you shut a water valve off fast it causes a water hammer ( Fire service term). So after time these plastic joints can fail. I am sure they will sell this to the public and it will be they way off the future, just not mine!

BK
bksaun
 
Stoker Coal Boiler: Hybrid, Gentleman Janitor GJ-6RSU/ EFM 700
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Pea Stoker/Bit, Pea or Nut Anthracite
Stove/Furnace Make: Hitzer/ EFM-Gentleman Janitor
Stove/Furnace Model: 503 Insert/ 700/GJ-62


Re: plastic plumbing

PostBy: coalkirk On: Wed Dec 12, 2007 10:42 am

Hate to disagree but if plastic joints are failing, they weren't properly primed and glued. CPVC, which is the type used for domestic water supply, has been around for along time without any problems. The glue is actually a solvent and the pipes "weld" to each other when properly installed. There are problems with another plastic material, polybutylene. This material deteriorates from the chlorine in municpal water and will always break.
Having said that, CPVC should not be used for hydronic heat as it has a maximum temperature that should not be exceeded. For domesitc water use, it's bullet proof.
coalkirk
 
Stoker Coal Boiler: Harman VF3000
Coal Size/Type: antrhcite/rice coal

Re: plastic plumbing

PostBy: Mastiffman On: Wed Dec 12, 2007 11:07 am

I've had CPVC splinter longways. My well water is only set at 25PSI, so it's not like it burst. It seems to have gotten brittle over time. Other areas I've been to smash it with a good squeeze.
I've used new CPVC to replace lines on the first floor, but when I redo the second floor I'm going all copper on the supply side.
You can't beat PVC for drain work.
Mastiffman
 

Re: plastic plumbing

PostBy: e.alleg On: Wed Dec 12, 2007 11:17 am

I guess you have to weigh the pros and cons. The pros of PVC is that it's a whole lot cheaper and for some it's easier to use. The cons is that it is weaker and ugly.
e.alleg
 
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: plastic plumbing

PostBy: Dallas On: Wed Dec 12, 2007 11:51 am

Actually, it seems as if PEX is the hot item now, with it's quick connect/disconnect fittings. Additionally, the have regular fittings and transition fittings.
Dallas
 
Hand Fed Coal Stove: Modified Russo C-35
Other Heating: Oil Hot Air
Stove/Furnace Make: Russo
Stove/Furnace Model: Modified C-35

Re: plastic plumbing

PostBy: e.alleg On: Wed Dec 12, 2007 1:42 pm

Dallas wrote:Actually, it seems as if PEX is the hot item now, with it's quick connect/disconnect fittings. Additionally, the have regular fittings and transition fittings.


My neighbor plumbed his house with pex. I'm not sold on it, it reminds me of the stuff we used to have on our antifreeze recycling machines at the garage, the clamps are like automotive clamps or thin crimp clamps. On the automotive stuff the clamps always leaked after a while. I'm sure it's good otherwise they wouldn't sell it, right?
e.alleg
 
Stove/Furnace Make: EFM
Stove/Furnace Model: 520

Re: plastic plumbing

PostBy: ken On: Wed Dec 12, 2007 9:32 pm

i'll stick with copper for anything that has pressure on it. can't beat PVC for drains and septic work.
ken
 
Stove/Furnace Make: Keystoker - Rice Coal
Stove/Furnace Model: 75K - Bay Window - Direct Vent

Re: plastic plumbing

PostBy: jpen1 On: Wed Dec 12, 2007 9:43 pm

Pex is the way to go my friends. With crimp fittings it can even withstand being frozen and then being doubled for a baseball bat. try that with copper once :lol: . I had a vendor come into work trying to push this years ago saying it could od this so skeptical as I am I tried it. Needless to say I am sold on its use other than high temp applications.
jpen1
 
Stove/Furnace Make: Leisure Line
Stove/Furnace Model: 110 Boiler

Re: plastic plumbing

PostBy: Yanche On: Wed Dec 12, 2007 9:48 pm

What pipe material is best is dependent on local conditions. My well water ph is 5.7, very acidic. Type M copper is full of holes in 3 years, type L in 5 years. PVC and CPVC installed per manufactures specifications will last many, many decades. I only install plumbing fixtures that are plastic on the inside, nothing else will hold up. Public water system around here add chemicals to reduce the harmful effects of the acidic water on copper. A few years ago those with copper pipes were having a rash of leaks. Problem was traced to the government owned water company reducing or eliminating the additives as a budget cost cutting move. In a closed pressurized hydronic system several pipe materials will work, metal or plastic, as long as the oxygen in the water is purged and/or neutralized and kept from re-entering. For PEX tubing this means you want the oxygen barrier type.
Yanche
 
Stoker Coal Boiler: Alternate Heating Systems S-130
Coal Size/Type: Anthracite Pea

Re: plastic plumbing

PostBy: Richard S. On: Thu Dec 13, 2007 1:31 am

Note the original poster was spammer, I left this open for discussion amongst yourselves.
Richard S.
 
Stoker Coal Boiler: Van Wert VA1200
Coal Size/Type: Buckwheat/Anthracite

Re: plastic plumbing

PostBy: George-NJ On: Thu Dec 13, 2007 11:51 am

Pex has been used in europe for decades in both domestic h&c water & heating applications.

It's not the just the future, it's the now. most new homes are being built with it. The cost of
copper being through the roof combined with the cost & ease of installing the pex make it an easy choice for most.

The last house I built & sold I used all type L copper, just because I didn't want call backs, you can imagine the added cost. Now I'm using only Pex.

Now if I can only find an alternative to copper for electric wire... :idea:
George-NJ
 

Re: plastic plumbing

PostBy: Wood'nCoal On: Thu Dec 13, 2007 8:17 pm

George-NJ wrote:
Now if I can only find an alternative to copper for electric wire... :idea:



Remember aluminum wire? That worked out well. I think copper is here to stay. :!:
Wood'nCoal
 
Stoker Coal Boiler: 1959 EFM 350
Hand Fed Coal Stove: Harman Magnafire Mark I
Coal Size/Type: Rice and Chestnut
Other Heating: Fisher Fireplace Insert

Re: plastic plumbing

PostBy: George-NJ On: Fri Dec 14, 2007 7:26 am

Wood'nCoal wrote:
George-NJ wrote:
Now if I can only find an alternative to copper for electric wire... :idea:



Remember aluminum wire? That worked out well. I think copper is here to stay. :!:


No I didn't forget aluminum, it cost as much as the copper does.
George-NJ