SF Harmon Wood/Coal Boiler

SF Harmon Wood/Coal Boiler

PostBy: clayhunter On: Fri. Dec. 28, 2012 1:57 pm

Hi, I am new both to this site and trying to run a SF260 Harman coal/wood boiler and any help is greatly appreciated. This is the boiler that I have
Attachments
160042.jpg
(45.78 KiB) Viewed 92 times
View: New PagePopup • Select:BBCode
[nepathumb]38998[/nepathumb]
160123.jpg
(50.6 KiB) Viewed 28 times
View: New PagePopup • Select:BBCode
[nepathumb]38999[/nepathumb]
Last edited by clayhunter on Fri. Dec. 28, 2012 5:05 pm, edited 1 time in total.
clayhunter
 
Stove/Furnace Model: SF260 Harman Boiler

Visit Hitzer Stoves

Re: SF Harmon Wood/Coal Boiler

PostBy: KLook On: Fri. Dec. 28, 2012 1:58 pm

what help is needed? What is the problem? Pictures are very valuable. :)

Kevin
KLook
 
Stoker Coal Boiler: Harman VF 3000
Coal Size/Type: rice, bagged, Blaschak
Other Heating: Gas boiler backup/main
Stove/Furnace Model: VF 3000

Re: SF Harmon Wood/Coal Boiler

PostBy: KLook On: Fri. Dec. 28, 2012 1:59 pm

Sorry, Welcome to the site!!! :D

Kevin
KLook
 
Stoker Coal Boiler: Harman VF 3000
Coal Size/Type: rice, bagged, Blaschak
Other Heating: Gas boiler backup/main
Stove/Furnace Model: VF 3000

Re: SF Harmon Wood/Coal Boiler

PostBy: clayhunter On: Fri. Dec. 28, 2012 5:12 pm

I am having a problem trying to get the draft set right so that the coal either doesn't burn up so fast or that the coals go out. It seems there is no halfway with this for me. Everything is manual, its not one of those that are fed mechanically. Is there suppose to be some kind of damper on the pipe that goes to the chimney, I am thinking about that since the only way I have to control the draft is with the ash door, and the 2 knobs on the feed door.
clayhunter
 
Stove/Furnace Model: SF260 Harman Boiler

Re: SF Harmon Wood/Coal Boiler

PostBy: KLook On: Fri. Dec. 28, 2012 5:17 pm

Ah, yes. You should have a barometric damper if you are burning coal. Some use it for wood also but this is a contentious issue. Other would say you should have a MPD or manual draft or butterfly damper in the stovepipe. Or both. This can be contentious issue also. You must have something to reduce the draft because it is sucking your heat up the chimney. And you have to come up with a manometer to measure the draft. Sounds complicated. Do a few searches on here and learn from what has been written before.

Kevin
KLook
 
Stoker Coal Boiler: Harman VF 3000
Coal Size/Type: rice, bagged, Blaschak
Other Heating: Gas boiler backup/main
Stove/Furnace Model: VF 3000

Re: SF Harmon Wood/Coal Boiler

PostBy: KLook On: Fri. Dec. 28, 2012 5:20 pm

There should be a manual for the draft settings for that Harman. Others have them and will weigh in when they see the post. That will tell you how much draft it calls for.

Kevin
KLook
 
Stoker Coal Boiler: Harman VF 3000
Coal Size/Type: rice, bagged, Blaschak
Other Heating: Gas boiler backup/main
Stove/Furnace Model: VF 3000

Re: SF Harmon Wood/Coal Boiler

PostBy: KLook On: Fri. Dec. 28, 2012 5:26 pm

nepacrossroads.com/about14727.html

Something in here might help
KLook
 
Stoker Coal Boiler: Harman VF 3000
Coal Size/Type: rice, bagged, Blaschak
Other Heating: Gas boiler backup/main
Stove/Furnace Model: VF 3000

Re: SF Harmon Wood/Coal Boiler

PostBy: grumpy On: Fri. Dec. 28, 2012 5:28 pm

Welcome Clayhunter, are you a Trap shooter?
grumpy
 

Visit Hitzer Stoves

Re: SF Harmon Wood/Coal Boiler

PostBy: clayhunter On: Fri. Dec. 28, 2012 5:49 pm

grumpy wrote:Welcome Clayhunter, are you a Trap shooter?

sometimes but its just my last name and I like to hunt lol
clayhunter
 
Stove/Furnace Model: SF260 Harman Boiler

Re: SF Harmon Wood/Coal Boiler

PostBy: KLook On: Fri. Dec. 28, 2012 8:21 pm

I'll say it before Fred hollers at ya. Fill in your location and such, we won't steal ya!

Kevin
KLook
 
Stoker Coal Boiler: Harman VF 3000
Coal Size/Type: rice, bagged, Blaschak
Other Heating: Gas boiler backup/main
Stove/Furnace Model: VF 3000

Re: SF Harmon Wood/Coal Boiler

PostBy: dcrane On: Fri. Dec. 28, 2012 9:01 pm

Nice help Klook... that link leads to all kinds of helpful stuff on the Harman for him. I can say that my friend in Pembroke MA. had one of these and it worked fantastic with wood (he never did use coal because his wood was free), Im personally a coal guy but I was impressed watching and feeling the heat this thing produced with wood!
dcrane
 
Hand Fed Coal Stove: Crane 404

Re: SF Harmon Wood/Coal Boiler

PostBy: Dennis On: Fri. Dec. 28, 2012 9:05 pm

Dennis
 
Hand Fed Coal Boiler: AHS/WOC55-multi-fuel/wood,oil,coal
Coal Size/Type: Anthracite/stove size

Re: SF Harmon Wood/Coal Boiler

PostBy: wilder11354 On: Sat. Dec. 29, 2012 8:50 am

first thing I notice, is you don't have the automatic ash door draft controller setup on it. It works off an aquastat/relay setup from harmon(Johnson Contols). Get it and install, second I use a barometric draft controller, it works great on these stoves. I burn nut coal go 12 hours between tendings.

Secondly do you have a Harman installation manual for this boiler? if not its available at Harman website, down load it and use it to install Draft controller setup.
Attachments
PB260177.jpg
(81.64 KiB) Viewed 46 times
View: New PagePopup • Select:BBCode
Johnson Controls draft controller setup
[nepathumb]39020[/nepathumb]
PB260178.jpg
(80.72 KiB) Viewed 37 times
View: New PagePopup • Select:BBCode
Barometric draft in flue pipe
[nepathumb]39021[/nepathumb]
PC290217.JPG
(83.23 KiB) Viewed 50 times
View: New PagePopup • Select:BBCode
Johnson Controls setup, better picture.
[nepathumb]39023[/nepathumb]
wilder11354
 
Hand Fed Coal Boiler: Harman SF260 Boiler
Coal Size/Type: nut or pea, anthracite
Other Heating: crown oil boiler, backup.if needed

Re: SF Harmon Wood/Coal Boiler

PostBy: clayhunter On: Sat. Dec. 29, 2012 9:49 pm

your boiler looks just like mine except When my father in law (before he his alzheimer's disease worsened) installed it, he decided for what ever reason to not install the Aquastat controls, or the barometric draft in the flue pipe, I did find some of the parts in a box, and plan on buying the barometric draft, like I said I knew it need something. By the way, I am a she not a he, lol, and with all the help that everyone is giving me I think I can get this done.
clayhunter
 
Stove/Furnace Model: SF260 Harman Boiler

Re: SF Harmon Wood/Coal Boiler

PostBy: dcrane On: Sat. Dec. 29, 2012 10:19 pm

clayhunter wrote:your boiler looks just like mine except When my father in law (before he his alzheimer's disease worsened) installed it, he decided for what ever reason to not install the Aquastat controls, or the barometric draft in the flue pipe, I did find some of the parts in a box, and plan on buying the barometric draft, like I said I knew it need something. By the way, I am a she not a he, lol, and with all the help that everyone is giving me I think I can get this done.


ZOMG... he is a she :shock: welcome to the forum ma'am... guess we gotta watch our language now ;) LOL