Re: Manometer Loaner Program

PostBy: Devil505 On: Thu Oct 02, 2008 8:02 pm

LsFarm wrote:Keep watching the readings. record the outside temp and the winds from the weather channel.. and we'll try to find out if you really have a steady draft or not.


Will do!

Nice to have the stove going again. It will be going down into the 40's at night now so I may just keep it idling from now on. (if we get back into a warm spell, I'll shut it back down though)
Devil505
 
Stove/Furnace Make: Harman
Stove/Furnace Model: TLC-2000

Re: Manometer Loaner Program

PostBy: Devil505 On: Sat Oct 04, 2008 10:26 am

What would be an ideal/good manometer reading for a chimney about 24-26' high?

My normal readings, so far are right around .03 going up to a max. of .07 during reloading with ash door open & fire pretty lively.
Devil505
 
Stove/Furnace Make: Harman
Stove/Furnace Model: TLC-2000

Re: Manometer Loaner Program

PostBy: Devil505 On: Sun Oct 05, 2008 7:20 pm

53* outside, Mag stove temp 150*, manometer reading .02

Have the the TLC full now but just idling. Manometer is reading between .02 &.03.........Full stove doesn't ssem to have changed things at all. Still very low manometer readings??
Attachments
003.JPG
(165.13 KiB) Viewed 96 times
View: New PagePopup • Select:BBCode
[nepathumb]6845[/nepathumb]
004.JPG
(160.92 KiB) Viewed 89 times
View: New PagePopup • Select:BBCode
[nepathumb]6846[/nepathumb]
Devil505
 
Stove/Furnace Make: Harman
Stove/Furnace Model: TLC-2000


Re: Manometer Loaner Program

PostBy: LsFarm On: Sun Oct 05, 2008 11:26 pm

I'm amazed that your stove burns without problems with that low draft.. lets see what it does when the fire is cranking, the temp is in the teens and the wind is howling.

Greg
LsFarm
 
Stoker Coal Boiler: Axeman Anderson 260
Hand Fed Coal Boiler: Self-built 'Big Bertha' SS Boiler
Baseburners & Antiques: Keystone 11, Art Garland

Re: Manometer Loaner Program

PostBy: Devil505 On: Mon Oct 06, 2008 6:24 am

LsFarm wrote:'m amazed that your stove burns without problems with that low draft.. lets see what it does when the fire is cranking, the temp is in the teens and the wind is howling.


I'm guessing that my chimney is no longer air tight (I do have the outside clean out sealed) & getting air from somewhere, but I'm not going to complain in that I can keep (even fairly cool) fires burning & my coal usage is low. I'll keep posting my readings but, so far I have not seen any change due to a full coal load now. (It's sill pretty mild out so I haven't had the fire on anything but idle yet)
Devil505
 
Stove/Furnace Make: Harman
Stove/Furnace Model: TLC-2000

Re: Manometer Loaner Program

PostBy: morrisfamily3098 On: Tue Oct 21, 2008 9:25 am

I am not regeristing a draft on my stove pipe at all. i have take readings at 3 different points on my stove pipe and at a temp diff from 100F to 200F and still nothing. when i put the hose parallel to the airflow from my blower it registers aboutn .1 in/water. i do go from a 6in pipe to an 8 in could this cause enough of a velocity decrease to register no draft? i even got on the roof and felt very little air movement or heat. my chimney is close to 30 ft from the exit of the stove to the top of the cap. :bang:
morrisfamily3098
 
Stove/Furnace Make: Leisure Line
Stove/Furnace Model: Hyfire2

Re: Manometer Loaner Program

PostBy: wannabwarm On: Tue Oct 21, 2008 4:45 pm

Is the loaner program still in operation. Just completed install of New Yorker boiler and need to set draft. Thanks in advance. Steve
wannabwarm
 
Stove/Furnace Make: New Yorker Coal Boiler WC90
Stove/Furnace Model: oil (ouch)

Re: Manometer Loaner Program

PostBy: morrisfamily3098 On: Wed Oct 22, 2008 9:38 am

yes if you PM matthaus he will set you up. i currently have one and it is working good i just set the baro damper at.02 and have a decent draft now. at all different heat levels of the stove pipe. :dancing:
morrisfamily3098
 
Stove/Furnace Make: Leisure Line
Stove/Furnace Model: Hyfire2

Re: Manometer Loaner Program

PostBy: DavidL On: Thu Oct 30, 2008 9:23 pm

I received matthaus's loaner manometer yesterday. I wasn't sure how to hook it up with just the one hose with a metal nipple . I contacted matthaus and he said to attatch a ball inflation needle at the end of the hose and insert it in one of the screw holes in the stove pipe between the stove and baro; it worked out perfect. Thanks matthaus.

These are the readings I got.

Outside temp: 30
Wind: none
Baro set at .06

Idle reading:
magnetic thermometer on stove pipe: 100
Manometer W.C.: .025
Baro was 1/4 open

Open draft reading: (forced draft blower)
magnetic thermometer on stove pipe: 225
Manometer W.C.: .03
Baro was 1/2 open.

do these reading seem normal or should the baro be set for more draft.

Thanks,
Dave
DavidL
 
Stove/Furnace Make: Energy King
Stove/Furnace Model: 480EK

Re: Manometer Loaner Program

PostBy: WNY On: Thu Nov 13, 2008 7:47 pm

More people getting stoves, thought I would get this up on top of the threads.
WNY
 
Hot Air Coal Stoker Stove: Keystoker 90K, Leisure Line Hyfire I
Coal Size/Type: Rice
Stove/Furnace Make: Keystoker, LL & CoalTrol
Stove/Furnace Model: 90K, Hyfire I, VF3000 Soon

Re: Manometer Loaner Program

PostBy: Cyber36 On: Mon Nov 17, 2008 2:38 pm

[quote="DavidL"]I received matthaus's loaner manometer yesterday. I wasn't sure how to hook it up with just the one hose with a metal nipple . I contacted matthaus and he said to attatch a ball inflation needle at the end of the hose and insert it in one of the screw holes in the stove pipe between the stove and baro; it worked out perfect. Thanks matthaus.

These are the readings I got.

Outside temp: 30
Wind: none
Baro set at .06

Idle reading:
magnetic thermometer on stove pipe: 100
Manometer W.C.: .025
Baro was 1/4 open

Open draft reading: (forced draft blower)
magnetic thermometer on stove pipe: 225
Manometer W.C.: .03
Baro was 1/2 open.

do these reading seem normal or should the baro be set for more draft.
Anybody care to answer his question? I'm in the process of setting mine & am curious to the reply...........
Cyber36
 
Hand Fed Coal Stove: Marathon/Logwood

Re: Manometer Loaner Program

PostBy: DavidL On: Mon Nov 17, 2008 3:25 pm

cyber36,

here are my results.

Manometer Readings
DavidL
 
Stove/Furnace Make: Energy King
Stove/Furnace Model: 480EK

Re: Manometer Loaner Program

PostBy: johnstar On: Tue Jan 06, 2009 9:31 pm

I would like to get on the list for borrowing the Manometer
johnstar
 
Stove/Furnace Make: U.S. Stoves
Stove/Furnace Model: Clayton 1600M

Re: Manometer Loaner Program

PostBy: Matthaus On: Wed Jan 07, 2009 3:14 pm

Send me a PM and I'll get you on the list. Need your mailing address and contact phone number. :)
Matthaus
 
Stoker Coal Boiler: Leisure Line WL110 Dual Fuel, natural gas
Hot Air Coal Stoker Stove: Leisure Line Lil' Heater (rental house)
Coal Size/Type: Rice and Buckwheat Anthracite

Re: Manometer Loaner Program

PostBy: bde-19547 On: Sat Jan 10, 2009 1:56 pm

I would like to get on the list to borrow the Manometer too. Thanks
bde-19547
 
Stoker Coal Boiler: VF3000
Coal Size/Type: rice
Stove/Furnace Make: Harman
Stove/Furnace Model: VF3000