Can I Use 6" Flue on EFM 520?

Post Reply
 
wdjacobs
New Member
Posts: 8
Joined: Thu. Jan. 31, 2013 7:54 pm

Post by wdjacobs » Thu. Jan. 31, 2013 8:10 pm

I'm thinking of buying a df 520, which recommends an 8" flue. I have 6" round steel flue pipe. Can it be done?

 
User avatar
Scottscoaled
Member
Posts: 2812
Joined: Tue. Jan. 08, 2008 9:51 pm
Location: Malta N.Y.
Stoker Coal Boiler: EFM 520, 700, Van Wert 800 GJ 61,53
Baseburners & Antiques: Magic Stewart 16, times 2!
Coal Size/Type: Lots of buck
Other Heating: Slant Fin electric boiler backup

Post by Scottscoaled » Thu. Jan. 31, 2013 9:34 pm

Yes it can be done. I used 6" for several years until I got the chimney built. It doesn't work good if you are going to use it on higher settings. I used mine on 4 and 5 teeth feed with the same air and didn't have issues until I jacked it up to 6 and above air. You can also get a little help with a draft inducer like several other members are successfully running.


 
User avatar
stoker-man
Verified Business Rep.
Posts: 2071
Joined: Mon. Nov. 19, 2007 9:33 pm
Location: Lehigh Valley, PA
Hand Fed Coal Boiler: 1981 efm wcb-24 in use 365 days a year
Coal Size/Type: Anthracite/Chestnut
Other Heating: Hearthstone wood stove

Post by stoker-man » Fri. Feb. 01, 2013 5:28 am

I know it's done. But if you run into a fire code inspector, he will only allow 7" (or larger). It pertains to the BTUH output of your unit, not how well it works in your personal setup.

 
wdjacobs
New Member
Posts: 8
Joined: Thu. Jan. 31, 2013 7:54 pm

Post by wdjacobs » Fri. Feb. 01, 2013 8:05 am

Thanks for your input - much appreciated!