Keystoker KA-6 Operation Guide.

Re: Keystoker Ka-6 operation guide.

PostBy: lzaharis On: Sun Feb 14, 2016 10:58 pm

GaryFerg wrote:
rednut.jpg
isnt this backwards? the manual says "Counterclockwise for less coal feed. Turn RED nut Clockwise for more coal feed. "


====================================================================================

No it is not backwards.

By shortening the stroke turning the red nut in the pusher plate travels
more and it pushes more coal across the fire grate per cycle OR total stroke length-

Think of it this way:

A concrete pump pushes concrete within a set volume. This Volume is the pusher ram connected to the hydraulic cylinder(ram) that pushes the ready mix concrete to where it needs to go.

The faster the rams move the more concrete it pumps. The Keystoker KAA6 pusher plate does the same thing with shorter cycles moving a greater amount of coal per hour than the longer stroke AS the longer stroke makes fewer cycles per hour.
lzaharis
 
Stoker Coal Boiler: Keystoker KAA-4-1 dual fuel boiler
Coal Size/Type: rice
Other Heating: kerosene for dual fuel Keystoker

Visit Leisure Line

Re: Keystoker Ka-6 operation guide.

PostBy: bobok On: Mon Feb 15, 2016 9:41 am

thanks, Bill
bobok
 
Stoker Coal Boiler: efm700 stoker, Pacific 350K boiler
Hand Fed Coal Boiler: D&S Machine hand fed
Coal Size/Type: stove / buck
Other Heating: Bethleham Dynatherm Oil boiler

Re: Keystoker Ka-6 operation guide.

PostBy: ShawnTRD On: Fri Sep 30, 2016 2:49 pm

bobok wrote:thanks, Bill


How did you make out?
ShawnTRD
 
Stoker Coal Boiler: Keystoker KA6 (New in April 2014)
Coal Size/Type: Anthracite Rice
Other Heating: Weil Mclain WGO-2 (Net 75k BTU)