Power Vent Leisure Line 110 Boiler

Post Reply
 
User avatar
klim1972
Member
Posts: 74
Joined: Tue. Nov. 01, 2011 11:15 am
Location: lake ariel Pa
Stoker Coal Boiler: EFM df 520
Coal Size/Type: Buck

Post by klim1972 » Tue. Mar. 19, 2013 9:27 pm

Looking to power vent my 110 just wanted to know if it is a pain to do so and what it entails . The wiring part I mean to say not putting hole through wall


 
Matthaus
Member
Posts: 1923
Joined: Mon. Oct. 02, 2006 8:59 am
Location: Berwick, PA and Ormand Beach FL

Post by Matthaus » Wed. Mar. 20, 2013 7:18 am

You will need a 5AF power vent kit from Leisure line and a fan prover switch for oil operation. Wiring involves inserting the fan prover and WMO-1 flue safety switch into the power circuit to prevent operation in the event the power vent is not providing draft. The manual for the power vent shows part of the wiring details and the fan prover instructions will provide the rest. I would recommend fixing the chimney. :)