PostBy: em On: Wed May 08, 2013 12:04 am

Hi I have a problem. I had this timer put on a year and a half ago and it has been working like a charm. Well today my furnace ran and ran all day (I wasn't home and whrn i got home it must have been 150 degrees. Felt like a house sized sauna! The timer rotates but never shuts off. Any Ideas?
em
 

Re: Timer C8835

PostBy: whistlenut On: Wed May 08, 2013 7:49 am

Unless you like surprises, I'd disconnect that timer immediately and replace it. You know you can use an 8865, 8845, etc. Do it now! :idea: :idea: :idea: :idea: :!: You can replace the timer motor if you can get the mechanism, so do what you are comfortable with. I assume you have looked over the operation of the timer, and I have never seen one fail in this way. Remember you can pull the pins for now and your boiler will work fine without the timer, but the out-fire risk is present.
Good luck!
whistlenut
 
Stoker Coal Boiler: AA130's,260's, AHS130&260's,EFM900,GJ&VanWert
Hand Fed Coal Boiler: Franks Boiler,Itasca415,NYer130,Van Wert
Hot Air Coal Stoker Furnace: Yellow Flame
Hot Air Coal Stoker Stove: Alaska-4,Keystoker-2,
Hand Fed Coal Stove: Alaska,Gibraltor,Keystone,Vc Vigilant 2
Hand Fed Coal Furnace: Van Wert, NYer's, Ford,Jensen.
Coal Size/Type: Rice,Buck,Pea,Nut&Stove
Other Heating: Oil HWBB

Re: Timer C8835

PostBy: em On: Wed May 08, 2013 9:04 am

Hi, Ill think Ill have my repairman just replace the timer or call him today and at least have him look at it to see what he thinks. Cold showers are not my style : ) I use the furnace all year to heat my water.
em
 

Visit Lehigh Anthracite

Re: Timer C8835

PostBy: McGiever On: Wed May 08, 2013 9:06 pm

It just may not be the timer that is bad.

Better check that the Aquastat isn't the culprit.
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hot Air Coal Stoker Stove: HARMAN MAGNUM
Hand Fed Coal Stove: RADIANT HOME AIR BLAST
Baseburners & Antiques: OUR GLENWOOD 111 BASEBURNER "1908"
Coal Size/Type: PEA / ANTHRACITE, NUT-STOVE / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek

Re: Timer C8835

PostBy: Rob R. On: Wed May 08, 2013 10:14 pm

A few minutes with a voltage meter should sort it out. If there is power at the NO terminal in the timer all the time, the timer is messed up. If the timer is working properly, see if something is calling for heat that shouldn't be...a staple through a thermostat wire, etc. The aquastat could be faulty...turn the high limit way down and see if it prevents the stoker from running.
Rob R.
 