Pioneer Rear Vent Coal-trol Question

Pioneer Rear Vent Coal-trol Question

PostBy: pete8116 On: Tue Jun 25, 2013 5:12 pm

I'm having my new Pioneer Rear Vent delivered later today.
I have my own Coal-trol. What should I set the Minimum Stoker and the Maximum Stoker Rate too?
Any other settings I should worry about?
Thanks for the info.
pete8116
 
Stoker Coal Boiler: Leisure Line Pioneer Rear Vent

Re: Pioneer Rear Vent Coal-trol Question

PostBy: Flyer5 On: Tue Jun 25, 2013 7:16 pm

Try 36 max and 5 min. Go from there it should get you close.
Flyer5
 
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer

Re: Pioneer Rear Vent Coal-trol Question

PostBy: pete8116 On: Wed Jun 26, 2013 7:35 am

Thanks,
Mark, for Coal Stoves and More set the stove up
yesterday evening. I'm looking forward to many
warm winters with it.
pete8116
 
Stoker Coal Boiler: Leisure Line Pioneer Rear Vent