I built a new pipe connection from my stove to the chimney, both are the same length.

The old one had a uphill slant from stove to chimney of approximately 5 inches.

The new pipe has an uphill slant from stove to chimney of approximately 9 inches.

Will the newer connection provide a better draft?

I guess what I am asking is "as slant increases, does draft increase"?

Appreaiet your thoughts.

thanks!

 
User avatar
freetown fred
Member
Posts: 30300
Joined: Thu. Dec. 31, 2009 12:33 pm
Location: Freetown,NY 13803
Hand Fed Coal Stove: HITZER 50-93
Coal Size/Type: BLASCHAK Nut

Post by freetown fred » Wed. Jul. 24, 2013 10:16 am

Pix---gotta have pix--- ;)

 
jrn8265
Member
Posts: 930
Joined: Tue. Jul. 22, 2008 11:52 am
Location: Near Coal Country, PA

Post by jrn8265 » Wed. Jul. 24, 2013 11:52 am

Does a steeper pipe angle from Stove to chimney provide for better draft on a warm day then a less steeped pipe?

 
franco b
Site Moderator
Posts: 11417
Joined: Wed. Nov. 05, 2008 5:11 pm
Location: Kent CT
Hand Fed Coal Stove: V ermont Castings 2310, Franco Belge 262
Baseburners & Antiques: Glenwood Modern Oak 114
Coal Size/Type: nut and pea

Post by franco b » Wed. Jul. 24, 2013 12:15 pm

jrn8265 wrote:Does a steeper pipe angle from Stove to chimney provide for better draft on a warm day then a less steeped pipe?
A steeper pipe has less resistance so will draft better but the increase would be very slight going from 5 to 9.


 
jrn8265
Member
Posts: 930
Joined: Tue. Jul. 22, 2008 11:52 am
Location: Near Coal Country, PA

Post by jrn8265 » Wed. Jul. 24, 2013 12:18 pm

Thanks! No pics, sorry!

 
User avatar
Lightning
Site Moderator
Posts: 14669
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Thu. Jul. 25, 2013 6:29 pm

I'm gonna venture to say that the increased angle may help some but would most likely be un measurable. My reason for this is because the draft or negative pressure if you will, is generated by the warm flue gases rising in the vertical section of your chimney.

Hypothetically you could have a flue pipe exit your stove and angle downward several feet to a chimney and it would draft just fine. Getting the draft started though would be challenging hahaha. Think of it as a siphon only upside down.

 
User avatar
dcrane
Verified Business Rep.
Posts: 3128
Joined: Sun. Apr. 22, 2012 9:28 am
Location: Easton, Ma.
Hand Fed Coal Stove: Crane 404

Post by dcrane » Thu. Jul. 25, 2013 8:53 pm

franco b wrote:
jrn8265 wrote:Does a steeper pipe angle from Stove to chimney provide for better draft on a warm day then a less steeped pipe?
A steeper pipe has less resistance so will draft better but the increase would be very slight going from 5 to 9.
Franco's got this :clap: less resistance, less angles = increased draft... but in your case it may not even be measurable without some seriously computerized testing gear.