High Fire on a DF520

Post Reply
 
chlop
New Member
Posts: 12
Joined: Thu. Oct. 30, 2008 5:12 pm

Post by chlop » Sun. Aug. 18, 2013 11:41 am

Someone recently told me my fire seems to be very high above the pot----about two inches. Now, except for outfires during hot and humid days, the boiler has burned impeccably for the time I've had it, about five years. Right now, I have the low water temp at 130 and the high at 190, while the feed is at two and the air at about three. Anyway, should the fire be that high above the pot?


 
User avatar
Rob R.
Site Moderator
Posts: 18004
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Sun. Aug. 18, 2013 12:01 pm

I have never seen what you described, even when running 8 teeth. Shut down and carefully check the burn plates for plugged holes...especially deep in the pot.

I suspect your feed and air settings may be partially to blame, for both the fire appearance and the outfires. When in doubt, try 4/4 and 2 minutes every half hr on the timer.