http://www.functionaldevices.com/images/diagrams/ ... B2401D.jpg
On left side of relay shows COM, 24VDC leg, 120V leg. ? is can 24V also be used instead of 120V on that leg?
RIB Relay 2401D
- wilder11354
- Member
- Posts: 1221
- Joined: Sat. Jan. 29, 2011 10:48 pm
- Location: Montrose, Pa.
- Hand Fed Coal Boiler: Harman SF260 Boiler
- Hand Fed Coal Stove: Hitzer 50-93
- Coal Size/Type: nut or pea, anthracite
- Other Heating: crown oil boiler, backup.if needed
- jpete
- Member
- Posts: 10829
- Joined: Thu. Nov. 22, 2007 9:52 am
- Location: Warwick, RI
- Hand Fed Coal Stove: Harman Mk II
- Coal Size/Type: Stove, Nut, Pea
- Other Heating: Dino juice
It's my understanding that low voltage can be used through high voltage contacts with no issue.
Not sure on a coil like this. Maybe too much resistance through the whole coil for 24V to work?
Not sure on a coil like this. Maybe too much resistance through the whole coil for 24V to work?
- Scottscoaled
- Member
- Posts: 2812
- Joined: Tue. Jan. 08, 2008 9:51 pm
- Location: Malta N.Y.
- Stoker Coal Boiler: EFM 520, 700, Van Wert 800 GJ 61,53
- Baseburners & Antiques: Magic Stewart 16, times 2!
- Coal Size/Type: Lots of buck
- Other Heating: Slant Fin electric boiler backup
Put 24volts to the white/yellow striped wire and white/blue striped wire, the contacts will cycle. Put 115volts to the white/yellow striped wire and the white/black striped wire, the contacts will cycle. Wire nut off the wire not being used.
- wilder11354
- Member
- Posts: 1221
- Joined: Sat. Jan. 29, 2011 10:48 pm
- Location: Montrose, Pa.
- Hand Fed Coal Boiler: Harman SF260 Boiler
- Hand Fed Coal Stove: Hitzer 50-93
- Coal Size/Type: nut or pea, anthracite
- Other Heating: crown oil boiler, backup.if needed
Thanks Scottcoaled... what I needed to know.
- 2001Sierra
- Member
- Posts: 2211
- Joined: Wed. May. 20, 2009 8:09 am
- Location: Wynantskill NY, 10 miles from Albany
- Hot Air Coal Stoker Stove: Keystoker 90 Chimney vent
- Coal Size/Type: Rice
- Other Heating: Buderus Oil Boiler 3115-34
I am using a RIB they are the nuts, will activate with multiple voltages as you found out, wire nut the unused.