PostBy: wilder11354 On: Wed Oct 02, 2013 8:43 pm

and it works as i hoped. Need to install another switch to shut down power to draft air control door on coal boiler. That way draft control servo won't run till i flip switch, once coal boilers been fired up for season. Will have to wait till boilers up and running to dial in the differential and offset settings on the stage module for primary circulator control set up.
PA020345.JPG
(81.05 KiB) Viewed 19 times
View: New PagePopup • Select:BBCode
[nepathumb]44184[/nepathumb]
PA020346.JPG
(83.47 KiB) Viewed 22 times
View: New PagePopup • Select:BBCode
[nepathumb]44185[/nepathumb]
PA020347.JPG
(81.72 KiB) Viewed 10 times
View: New PagePopup • Select:BBCode
[nepathumb]44186[/nepathumb]
PA020348.JPG
(81.89 KiB) Viewed 16 times
View: New PagePopup • Select:BBCode
[nepathumb]44188[/nepathumb]
wilder11354
 
Hand Fed Coal Boiler: Harman SF260
Coal Size/Type: nut or pea, anthracite
Other Heating: crown oil boiler, backup.if needed

Re: Its Alive...

PostBy: freetown fred On: Wed Oct 02, 2013 10:21 pm

Nice Billy--don't shoot your eye out ;)
freetown fred
 
Hand Fed Coal Stove: HITZER 50-93
Coal Size/Type: BLASCHAK Nut/Stove mix

Re: Its Alive...

PostBy: Freddy On: Thu Oct 03, 2013 7:31 am

Nice! Glad you got your brain wrapped around it & got 'er done!
Freddy
 
Stoker Coal Boiler: Axeman Anderson 130 (pea)
Hot Air Coal Stoker Stove: Reading piece o' junk in the barn (rice)
Coal Size/Type: Pea size, Superior, deep mined


Re: Its Alive...

PostBy: waldo lemieux On: Thu Oct 03, 2013 8:00 am

And I was impressed with the baler project :jawdrop:
waldo lemieux
 
Stove/Furnace Make: efm
Stove/Furnace Model: s-20

Re: Its Alive...

PostBy: titleist1 On: Thu Oct 03, 2013 8:06 am

that one j-box reminds me of smitty's breaker panel, minus the jumper cables of course!! :P
titleist1
 
Hot Air Coal Stoker Stove: Harman Mag Stoker (old style) one in basement, one in workshop
Hand Fed Coal Stove: Harman Mark III on standby for long power outages
Coal Size/Type: Rice/Anthracite; Nut/Anthracite

Re: Its Alive...

PostBy: wilder11354 On: Thu Oct 03, 2013 7:29 pm

Just need to figure what i want to hook up to two more circuits in manual transfer switch for generator. All the essentials are hooked in; heating system, frig, power to LR wall W/tv. furnance room outlets for cable service/computer, and one wall in kitchen, range/ microwave. decisions decisons.

Will order up one spare RIB24Z and 2401D relay in case one ever fails. No heat = frozen pipes. as far as 24V side can always use 2 small auto batterys wired in parallel if needed and a set of Smiity's jumper cables. :eek2:
wilder11354
 
Hand Fed Coal Boiler: Harman SF260
Coal Size/Type: nut or pea, anthracite
Other Heating: crown oil boiler, backup.if needed

Re: Its Alive...

PostBy: wilder11354 On: Wed Oct 23, 2013 8:43 pm

Been burning steady since monday evening,(load mishap sunday), can tell from how the circulators are wired, to zones, and such, i beleive my coal consumption will be a bit less this year from the change, and coal boilers loss> recovery time is a lot quicker. Know its not 15* out, but it should be better heat when it is. Guess you learn as you go. Now i just need to get some 1" fiberglass insulation on hot feed lines under house, and see how much more i gain from that.
wilder11354
 
Hand Fed Coal Boiler: Harman SF260
Coal Size/Type: nut or pea, anthracite
Other Heating: crown oil boiler, backup.if needed