Manometer placement (pic attached)

Manometer placement (pic attached)

PostBy: IH Cub On: Sun Oct 27, 2013 2:51 pm

I was hoping someone could advise me on where to put a manometer. Can it go after the barometric damper? On my stove, the damper comes a few inches from the stove (no room to put the Mano before the Baro).

Thanks

image.jpg
(212.2 KiB) Viewed 48 times
View: New PagePopup • Select:BBCode
Picture of my piping
[nepathumb]44960[/nepathumb]
IH Cub
 
Hand Fed Coal Stove: Harman SF-250
Coal Size/Type: Chestnut
Other Heating: Propane baseboard hot water
Stove/Furnace Make: Harman
Stove/Furnace Model: SF250

Re: Manometer placement (pic attached)

PostBy: lsayre On: Sun Oct 27, 2013 2:57 pm

The manometer needs to go between the stove and the barometric damper.
lsayre
 
Stoker Coal Boiler: AHS S130 Coal Gun
Coal Size/Type: Anthracite Pea
Other Heating: Resistance Boiler (if I ever get it fixed)

Re: Manometer placement (pic attached)

PostBy: I'm On Fire On: Sun Oct 27, 2013 5:11 pm

Put it right at the stove outlet.
I'm On Fire
 
Hand Fed Coal Stove: DS Machines DS-1600 Hot Air Circulator

Visit Hitzer Stoves

Re: Manometer placement (pic attached)

PostBy: mozz On: Sun Oct 27, 2013 5:30 pm

Drill a small hole, maybe 1/8", place copper or steel tubing in the hole, this is where the manometer will hook up to so the plastic hose doesn't melt.
mozz
 
Stoker Coal Boiler: Axeman Anderson 1982 AA-130 Steam

Re: Manometer placement (pic attached)

PostBy: Lightning On: Sun Oct 27, 2013 6:59 pm

Heres a link to another mano thread that might help....

manometer
Lightning
 
Hand Fed Coal Furnace: Clayton 1537G
Coal Size/Type: Nut Size / White Ash

Re: Manometer placement (pic attached)

PostBy: McGiever On: Sun Oct 27, 2013 8:21 pm

No no no, the mano gets mounted on the wall...only insert the metal tube in the pipe...geez guys. :doh:
McGiever
 
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hot Air Coal Stoker Stove: HARMAN MAGNUM
Hand Fed Coal Stove: RADIANT HOME AIR BLAST
Baseburners & Antiques: OUR GLENWOOD 111 BASEBURNER "1908"
Coal Size/Type: PEA / ANTHRACITE, NUT-STOVE / ANTHRACITE
Other Heating: Ground Source Heat Pump
Stove/Furnace Make: Hydro Heat /Mega Tek

Visit Hitzer Stoves