problem with pioneer le

problem with pioneer le

PostBy: tster On: Tue Nov 26, 2013 2:23 pm

I have a pioneer le with coaltrol that has given no problem til now. I'm having issue maintaining daytime set point. I have had the set point at 73 for several days with a min of 6 and a max of 47.At these settings the actual temperature swings from 70 to 76 instead of the previous plus/minus 1 degree, Any suggestions on how to decrease this swing is appreciated.
tster
 
Stove/Furnace Make: leisure line
Stove/Furnace Model: pioneer le

Re: problem with pioneer le

PostBy: mozz On: Tue Nov 26, 2013 5:21 pm

Have you taken out the grates and cleaned all the fine holes through which the air blows?
mozz
 
Stoker Coal Boiler: Axeman Anderson 1982 AA-130 Steam

Re: problem with pioneer le

PostBy: tster On: Wed Nov 27, 2013 10:53 am

Thanks for the suggestion . I will give it ago and see what happens.
tster
 
Stove/Furnace Make: leisure line
Stove/Furnace Model: pioneer le

Visit Leisure Line Stove

Re: problem with pioneer le

PostBy: Flyer5 On: Wed Nov 27, 2013 10:41 pm

Have you changed the HLF setting in the coal trol? It should be 0 . If you remove the grate make sure to re install with the gasket along the back most times it can be reused. But it must be there. Look on our forum under tips and tricks. Dave
Flyer5
 
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer

Re: problem with pioneer le

PostBy: tster On: Thu Nov 28, 2013 9:45 am

I haven't pulled the grate yet,as I'm waiting for a warmer day to shut down the stove,but will double check the gasket. I do have the HLF set on 3 as I have an old farmhouse with moderate insulation. I will reset to 0 and see what happens. Thanks to all , and have a great and safe Thanksgiving!
tster
 
Stove/Furnace Make: leisure line
Stove/Furnace Model: pioneer le

Re: problem with pioneer le

PostBy: Flyer5 On: Thu Nov 28, 2013 9:48 am

tster wrote:I haven't pulled the grate yet,as I'm waiting for a warmer day to shut down the stove,but will double check the gasket. I do have the HLF set on 3 as I have an old farmhouse with moderate insulation. I will reset to 0 and see what happens. Thanks to all , and have a great and safe Thanksgiving!



3 is a pretty wild setting. It is rare that you would go more than 1 in a home.
Flyer5
 
Stoker Coal Boiler: Leisure Line WL110
Hot Air Coal Stoker Stove: Leisure Line Pioneer

Visit Leisure Line Stove