Finally Installed Manometer!

 
User avatar
Lightning
Site Moderator
Posts: 14652
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Mon. Dec. 23, 2013 2:55 pm

ridgeracing wrote:Fixed, not adjustable. I believe I just cant turn stove down below 250deg. during warm/rainy days (above 50)
I don't mean to add anything negative but I'm having trouble understanding why a stove manufacturer chooses to have a fixed secondary air on their product. :?

 
User avatar
lsayre
Member
Posts: 21781
Joined: Wed. Nov. 23, 2005 9:17 pm
Location: Ohio
Stoker Coal Boiler: AHS S130 Coal Gun
Coal Size/Type: Lehigh Anthracite Pea
Other Heating: Resistance Boiler (13.5 KW), ComfortMax 75

Post by lsayre » Mon. Dec. 23, 2013 3:21 pm

Lightning wrote:I don't mean to add anything negative but I'm having trouble understanding why a stove manufacturer chooses to have a fixed secondary air on their product. :?
The added cost factor perhaps?

 
User avatar
Sunny Boy
Member
Posts: 25517
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Mon. Dec. 23, 2013 3:57 pm

lsayre wrote:
Lightning wrote:I don't mean to add anything negative but I'm having trouble understanding why a stove manufacturer chooses to have a fixed secondary air on their product. :?
The added cost factor perhaps?
Simplifying it could also make it more attractive because of one less variable for new owners to have to learn.

And/or, to save money, both before and after the sale, some companies make design choices based on avoiding customer complaints and phone time dealing with them. Simple = less complaints. :D Complex = more phone calls from complaining customers ! :mad:

Paul


 
KingCoal
Member
Posts: 4833
Joined: Wed. Apr. 03, 2013 1:24 pm
Location: Elkhart county, IN.
Hand Fed Coal Stove: 1 comforter stove works all iron coal box stove, seventies.
Baseburners & Antiques: 2014 DTS C17 Base Burner, GW #6, GW 113 formerly Sir Williams, maybe others at Pauliewog’s I’ve forgotten about
Coal Size/Type: Nut Anth.
Other Heating: none

Post by KingCoal » Mon. Dec. 23, 2013 4:15 pm

Lightning wrote:
ridgeracing wrote:Fixed, not adjustable. I believe I just cant turn stove down below 250deg. during warm/rainy days (above 50)
I don't mean to add anything negative but I'm having trouble understanding why a stove manufacturer chooses to have a fixed secondary air on their product. :?
i'm sure I can't speak to the reasoning, but I have to say that once I had enough experience with the DSM 1400 I have concluded that the sweet spot is -.04 / -.05 WC and bi-metal where ever you are comfortable. beyond that the hopper and the intake flap will carry it, the secondaries take care of themselves.

even when my stove top has been 500* for days the intake flap is almost stationary at 1/8" or less. I can't imagine how high this stove would burn if you let it.

 
User avatar
ridgeracing
Member
Posts: 160
Joined: Mon. Mar. 05, 2012 8:59 pm
Location: Elizabethtown, PA
Hand Fed Coal Stove: DS Machine Stove

Post by ridgeracing » Mon. Dec. 23, 2013 6:20 pm

KingCoal wrote:where are you measuring your stove temp. ?
Top, center, rear

 
User avatar
ridgeracing
Member
Posts: 160
Joined: Mon. Mar. 05, 2012 8:59 pm
Location: Elizabethtown, PA
Hand Fed Coal Stove: DS Machine Stove

Post by ridgeracing » Mon. Dec. 23, 2013 6:30 pm

Not really a problem, I just have to keep it 240deg and above when temps are above 55 outside. When its below 55 outside I have had it running 200deg. with no problems or loss of draft