Small Boiler in an 8X10 Shed? Will It Work?

 
oldsch
New Member
Posts: 12
Joined: Tue. Feb. 05, 2013 11:08 pm
Location: W.PA

Post by oldsch » Mon. Jan. 20, 2014 8:51 pm

I've been kicking around the idea of a coal boiler. I currently heat with a hand fired coal stove and have an oil fired boiler and cast iron rads as backup. The radiators give off wonderful heat when I use them but I can't stand buying the oil.The boiler is about 90k BTU.
One problem is that I don't have a basement but I do have a 8x10 shed about 20 ft from the house. So, are there any smaller boilers that would fit in a shed. EFM350? Others?
Would there be any room to spare for a small coal bin?
Thanks.


 
User avatar
windyhill4.2
Member
Posts: 6072
Joined: Fri. Nov. 22, 2013 2:17 pm
Location: Jonestown,Pa.17038
Stoker Coal Boiler: 1960 EFM520 installed in truck box
Hand Fed Coal Stove: Crane 404 with variable blower
Coal Size/Type: 404-nut, 520 rice ,anthracite for both

Post by windyhill4.2 » Mon. Jan. 20, 2014 9:22 pm

Welcome,oldsch ,you have an earlier join date than me but yet you are a new member ?? Your shed idea will work,but it will need to be insulated all around..floor,ceiling,walls,not sure on the brand/model that would fit best but some boiler experts will chime in soon & advise.Why a shed,can't you put it where the oil boiler is ? I will be waiting with you to hear advice on this as we are looking to go from OWB to coal boiler in the sometime future.

 
Pacowy
Member
Posts: 3555
Joined: Tue. Sep. 04, 2007 10:14 pm
Location: Dalton, MA
Stoker Coal Boiler: H.B. Smith 350 Mills boiler/EFM 85R stoker
Coal Size/Type: Buckwheat/anthracite

Post by Pacowy » Mon. Jan. 20, 2014 10:27 pm

I think the "New Member" designation is determined by the number of posts, not by the joining date.

oldsch, please check your private messages (envelope icon at top of page).

Thanks.

Mike

 
User avatar
Scottscoaled
Member
Posts: 2812
Joined: Tue. Jan. 08, 2008 9:51 pm
Location: Malta N.Y.
Stoker Coal Boiler: EFM 520, 700, Van Wert 800 GJ 61,53
Baseburners & Antiques: Magic Stewart 16, times 2!
Coal Size/Type: Lots of buck
Other Heating: Slant Fin electric boiler backup

Post by Scottscoaled » Mon. Jan. 20, 2014 11:00 pm

While 8x10 is certainly close, it is real possible to fit a 520 with a short extension auger. I put one in a small addition that was the same size off my barn and it worked well. You have to use an extension auger or you will have coal smell when your barrel gets low. A Van Wert would be a good choice as would a keystoker or a yellow flame. And yes, your building needs to be insulated. Don't forget to run a pvc conduit or two in with the underground pex. For power and a control or two. Good luck!

 
User avatar
StokerDon
Site Moderator
Posts: 7486
Joined: Mon. Nov. 11, 2013 11:17 am
Location: PA, Southern York County!
Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood

Post by StokerDon » Tue. Jan. 21, 2014 6:03 am

I am totaly biased but the Yellow Flame has a suprizingly small footprint, only 21"x36". I'm certin there are others withe a small footprint as well. You will also gain a very inexpensive way to heat domestic hot water! If you put it in the shed, you can run it all year. For a coal bin, you could either buy or build a smaller shed and use that as the coal bin, it doesn't take much of a shed to hold 5 ton or so.
YFstokerBoilerComplete 003.JPG

YF

.JPG | 107.3KB | YFstokerBoilerComplete 003.JPG
YFstokerBoilerComplete 007.JPG

YF

.JPG | 91KB | YFstokerBoilerComplete 007.JPG
YFfirstFire 006.JPG

YELLOW FLAME!!!

.JPG | 107.4KB | YFfirstFire 006.JPG
-Don

 
User avatar
windyhill4.2
Member
Posts: 6072
Joined: Fri. Nov. 22, 2013 2:17 pm
Location: Jonestown,Pa.17038
Stoker Coal Boiler: 1960 EFM520 installed in truck box
Hand Fed Coal Stove: Crane 404 with variable blower
Coal Size/Type: 404-nut, 520 rice ,anthracite for both

Post by windyhill4.2 » Tue. Jan. 21, 2014 6:45 am

Don, your Yellow Flame has a 21x36 base,but what is the overall or working footprint, i'm curious for my own situation. Working = space needed around it to fill hopper,maintenance,etc.,what space would you need if you were to partition boiler into its own room ? I think that would help give at least several of us a better idea of the space needed for our plans, should help oldsch to visualize his shed space working or not,thank you,nice boiler !!!!

 
User avatar
StokerDon
Site Moderator
Posts: 7486
Joined: Mon. Nov. 11, 2013 11:17 am
Location: PA, Southern York County!
Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood

Post by StokerDon » Tue. Jan. 21, 2014 10:08 am

The working area for my Yellow Flame is 6' by 9'. That includes space for the flue pipe, hopper, coal buckets, ashpans and a floor mouted expansion tank.

-Don


 
User avatar
windyhill4.2
Member
Posts: 6072
Joined: Fri. Nov. 22, 2013 2:17 pm
Location: Jonestown,Pa.17038
Stoker Coal Boiler: 1960 EFM520 installed in truck box
Hand Fed Coal Stove: Crane 404 with variable blower
Coal Size/Type: 404-nut, 520 rice ,anthracite for both

Post by windyhill4.2 » Tue. Jan. 21, 2014 10:17 am

Thanks,Don, woul that include any space to walk up to the hopper & dump a bucket of coal in or would the shed door need to be open for doing that ? 6x9 in 8x10 seems a bit snug.

 
Pacowy
Member
Posts: 3555
Joined: Tue. Sep. 04, 2007 10:14 pm
Location: Dalton, MA
Stoker Coal Boiler: H.B. Smith 350 Mills boiler/EFM 85R stoker
Coal Size/Type: Buckwheat/anthracite

Post by Pacowy » Tue. Jan. 21, 2014 10:37 am

I would suggest planning to turn the boiler "sideways" so that the blank side is parallel and close to one of the 8' walls of the shed. That way the side of the boiler with the ash door will be facing the center of the shed 3' or less from the wall. Depending upon the location of the door, that would leave about a 3x8 working area next to the boiler, and a 4x8 space for coal storage.

Mike

 
User avatar
D-frost
Member
Posts: 1182
Joined: Sun. Dec. 08, 2013 7:10 am
Location: Southern New Hampshire
Hand Fed Coal Stove: Harman MK ll
Hand Fed Coal Furnace: Yukon Eagle I (multi-fuel oil, wood/coal)
Baseburners & Antiques: Herald 'fireside oak'
Coal Size/Type: nut/stove-Blaschak/Lehigh

Post by D-frost » Tue. Jan. 21, 2014 10:48 am

Just a Thought- Buy a "doghouse coal boiler" and park it beside the 8x10 shed. Run the coal feeder into the shed.(Instant coal bin) And, the "doghouse is already insulated.

Cheers

 
User avatar
Sting
Member
Posts: 2983
Joined: Mon. Feb. 25, 2008 4:24 pm
Location: Lower Fox Valley = Wisconsin
Other Heating: OBSO Lennox Pulse "Air Scorcher" burning NG

Post by Sting » Tue. Jan. 21, 2014 12:14 pm

I am not fond of walking into the outdoors to check the fire -- I prefer to wear my jammies and slippers in the Boiler room

just cus it will fit in the space - doesn't mean it will be comfortable and convenient to work on or in!

Image

 
User avatar
StokerDon
Site Moderator
Posts: 7486
Joined: Mon. Nov. 11, 2013 11:17 am
Location: PA, Southern York County!
Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood

Post by StokerDon » Tue. Jan. 21, 2014 1:16 pm

I don't know Sting, I'm sure there are advantages to having your boiler in the "GETTAWAY VAN".

-Don

 
User avatar
StokerDon
Site Moderator
Posts: 7486
Joined: Mon. Nov. 11, 2013 11:17 am
Location: PA, Southern York County!
Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood

Post by StokerDon » Tue. Jan. 21, 2014 1:24 pm

windyhill4.2 wrote:Thanks,Don, woul that include any space to walk up to the hopper & dump a bucket of coal in or would the shed door need to be open for doing that ? 6x9 in 8x10 seems a bit snug.
The area behind the hopper is 6'x2.5'. There I have 4 coal buckets and the 14 gal expansion tank and enough room to load the hopper.

-Don

 
Penn507
Member
Posts: 41
Joined: Thu. Feb. 21, 2013 6:33 pm
Location: Toledo,Oh
Stoker Coal Boiler: EFM 520
Coal Size/Type: Rice

Post by Penn507 » Tue. Jan. 21, 2014 9:25 pm

If there is a will,there is a way. This is a EFM 520 in my shop 80 ft. from the house.

Attachments

image.jpg
.JPG | 119.5KB | image.jpg

 
User avatar
StokerDon
Site Moderator
Posts: 7486
Joined: Mon. Nov. 11, 2013 11:17 am
Location: PA, Southern York County!
Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood

Post by StokerDon » Tue. Jan. 21, 2014 9:31 pm