Coal fired hot water? I need help!

Coal fired hot water? I need help!

PostBy: Townsonbck On: Sat Feb 02, 2008 9:20 pm

I am trying to run my hot water through my stove. I have my heat exchanger and my tank. Have a bronze taco 007 pump and a regulater and blow off valve. My question is what do I do if the water gets to hot. boiling point! How or what can I do to cool it off besides running the water in the house.If I make a loop what do I need for hard ware to automaticly open to take the loop. I'm not to sure what I want to do here.
Thank you
Juston
Townsonbck
New Member
 
Posts: 11
Joined: Mon Jan 21, 2008 11:22 pm
Location: Western Ma
Stove/Furnace Make: Shenandoah
Stove/Furnace Model: Model R-77


Re: Coal fired hot water? I need help!

PostBy: traderfjp On: Mon Feb 04, 2008 1:49 pm

If there is too much heat and pressure in the system your PRV will open and let out the pressure. You could always run the extra heat through a baseboard or into a tub so the PRV doesn't blow off. I also wouldn't suggest making a loop unless you really know what you're doing. There are several companies that sell coils ready made.
Last edited by traderfjp on Mon Feb 04, 2008 7:04 pm, edited 1 time in total.
User avatar
traderfjp
Member
 
Posts: 1813
Joined: Wed Apr 19, 2006 10:32 pm
Location: New York
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing 3

Re: Coal fired hot water? I need help!

PostBy: lincolnmania On: Mon Feb 04, 2008 1:54 pm

like a baseboard heater? how bout some pex tubing in a 12x12 slab........would that be too much? i'm seriously thinking about a hot water coil myself.....i dont use a huge amount of hot water so most of it would go to heat in a baseboard heater?
lincolnmania
Member
 
Posts: 863
Joined: Fri Jan 26, 2007 10:55 pm
Location: newtown/zerbe pa
Stove/Furnace Make: efm alaska kenmore warm morn
Stove/Furnace Model: af150 kodiak

Re: Coal fired hot water? I need help!

PostBy: Richard S. On: Mon Feb 04, 2008 1:59 pm

You can loop it through a hot water heater. EFM Boiler Cold Water in Shower
User avatar
Richard S.
Mayor
 
Posts: 11049
Joined: Fri Oct 01, 2004 8:35 pm
Location: NEPA
Stove/Furnace Make: Van Wert
Stove/Furnace Model: VA1200

Re: Coal fired hot water? I need help!

PostBy: coalpower On: Wed Aug 19, 2009 2:31 pm

I actually unwired the thermostats on my electric hot water tank and set the temp at 130* on the bottom one. I use it as a switch to turn the taco pump on when the tank gets cold and off when the tank gets hot. I installed a tee in the drain and the pump comes off of there. And a tee where the relief valve goes put the valve back in the tee and this is where the heated water returns from the heat exchanger at the furnace. My furnace has two pumps. One at the water tank and one at the furnace that takes the furnace water and circulates it thru the exchanger. The switch turns both pumps on and off at the same time. I had to run an extra wire out to the furnace just For this. It's a $55.00 a month savings on electric.