ShawnTRD wrote:Then I have a problem?
Not if yer an outlaw like me.. :lol:

 
User avatar
coaledsweat
Site Moderator
Posts: 13766
Joined: Fri. Oct. 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Post by coaledsweat » Thu. Aug. 14, 2014 8:13 pm

A concrete block wall would cure that problem.

 
User avatar
ShawnTRD
Member
Posts: 519
Joined: Tue. Feb. 04, 2014 1:04 am
Location: Spencer, NY
Stoker Coal Boiler: Keystoker KA6 (New in April 2014)
Coal Size/Type: Anthracite Rice
Other Heating: Weil Mclain WGO-2 (Net 75k BTU)

Post by ShawnTRD » Thu. Aug. 14, 2014 8:52 pm

coaledsweat wrote:A concrete block wall would cure that problem.
4" on rollers?


 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Thu. Aug. 14, 2014 8:53 pm

And some people have buried outside oil tanks...or maybe their outlaws today too. ;)

 
User avatar
ShawnTRD
Member
Posts: 519
Joined: Tue. Feb. 04, 2014 1:04 am
Location: Spencer, NY
Stoker Coal Boiler: Keystoker KA6 (New in April 2014)
Coal Size/Type: Anthracite Rice
Other Heating: Weil Mclain WGO-2 (Net 75k BTU)

Post by ShawnTRD » Fri. Aug. 15, 2014 12:27 am

Well I wish I would have heard this earlier. I'll see my uncle (plumber) this Saturday. See what he says. Maybe I'll have to move the tank to the other side of the garage.

 
User avatar
NWBuilder
Member
Posts: 463
Joined: Tue. Jan. 04, 2011 11:43 am
Location: Norfolk, CT
Stoker Coal Boiler: Ahs 130
Coal Size/Type: Burning Pea anthracite

Post by NWBuilder » Fri. Aug. 15, 2014 8:08 am

I would move the tank since it will just be collecting dust soon.


 
User avatar
Rob R.
Site Moderator
Posts: 18004
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Fri. Aug. 15, 2014 9:03 am

If you have room for the oil tank somewhere else, I would move it.

 
User avatar
whistlenut
Member
Posts: 3548
Joined: Sat. Mar. 17, 2007 6:29 pm
Location: Central NH, Concord area
Stoker Coal Boiler: AA130's,260's, AHS130&260's,EFM900,GJ & V-Wert
Hand Fed Coal Boiler: Franks,Itasca 415,Jensen, NYer 130,Van Wert
Hot Air Coal Stoker Furnace: Alaska, EFM, Keystoker, Yellow Flame
Hot Air Coal Stoker Stove: Alaska, Keystoker-2,Leisure Line
Hand Fed Coal Stove: Alaska, Gibraltar, Keystone,Vc Vigilant 2
Hand Fed Coal Furnace: Ford, Jensen, NYer, Van Wert,
Baseburners & Antiques: Glenwoods
Coal Size/Type: Barley, Buck, Rice ,Nut, Stove
Other Heating: Oil HWBB

Post by whistlenut » Fri. Aug. 15, 2014 9:18 am

The tank is not a priority at this point, you can endure all the "outlaw" names.....it is what it is. Shaun, you can install a custom made steel strap/straps to the chimney where possible to make it more secure , even higher it need be. Wind can have one hell of an effect even on that small cross section. Anti seize every thing on that stoker before you slide it into place......side rails especially. They won't 'cooperate with a 9/16" wrench in a tight spot......