Should I Insulate KA6?
- ShawnTRD
- Member
- Posts: 513
- Joined: Tue. Feb. 04, 2014 1:04 am
- Location: Spencer, NY
- Stoker Coal Boiler: Keystoker KA6 (New in April 2014)
- Coal Size/Type: Anthracite Rice
- Other Heating: Weil Mclain WGO-2 (Net 75k BTU)
My Keystoker KA6 will be in the garage/basement. I have no intention of heating that area, and want the KA6 to use as little coal as it needs. So can/should I insulate the outside? Would I still be able to hang the sides?
- StokerDon
- Site Moderator
- Posts: 7486
- Joined: Mon. Nov. 11, 2013 11:17 am
- Location: PA, Southern York County!
- Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
- Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
- Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
- Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood
Even if you did want to heat the area where the boiler lives, there are better ways of doing it than leaving the boiler insulation off.
The boiler will be able to maintain temp much better if you insulate it well. I wouldn't worry about getting the covers back on if your going to increase the performance of your boiler with a good coat of insuation.
-Don
The boiler will be able to maintain temp much better if you insulate it well. I wouldn't worry about getting the covers back on if your going to increase the performance of your boiler with a good coat of insuation.
-Don
-
- Member
- Posts: 3555
- Joined: Tue. Sep. 04, 2007 10:14 pm
- Location: Dalton, MA
- Stoker Coal Boiler: H.B. Smith 350 Mills boiler/EFM 85R stoker
- Coal Size/Type: Buckwheat/anthracite
Yes you can/should insulate the boiler if you're not trying to heat that area. It doesn't take a lot of insulation to keep most of the heat where you want it; you shouldn't need so much that you can't get the jackets on.
Leaving the jackets off can work effectively when you are trying to heat the area the boiler is in. We did it in our old house and it immediately civilized the unheated basement and improved the "feel" of the first floor of a drafty old house, all without spending a nickel on radiation, piping or controls. It does use more coal; depends on the situation whether it's a good idea.
Mike
Leaving the jackets off can work effectively when you are trying to heat the area the boiler is in. We did it in our old house and it immediately civilized the unheated basement and improved the "feel" of the first floor of a drafty old house, all without spending a nickel on radiation, piping or controls. It does use more coal; depends on the situation whether it's a good idea.
Mike
- Rob R.
- Site Moderator
- Posts: 17980
- Joined: Fri. Dec. 28, 2007 4:26 pm
- Location: Chazy, NY
- Stoker Coal Boiler: EFM 520
- Hand Fed Coal Stove: Chubby Jr
Insulate the boiler and piping. Make sure the covers fit snugly together and stuff the openings around the pipe trappings with insulation. You do not want an air current through the gap between the covers and boiler.