Mr. Herald Install UPDATE!!! Am I Forgetting Any Thing?

Post Reply
 
User avatar
DePippo79
Member
Posts: 734
Joined: Tue. Mar. 05, 2013 3:17 pm
Location: Hampton, NH
Baseburners & Antiques: Glenwood Oak 40, Stanley Argand No. 30, Glenwood Modern Oak 114, Stanley Argand No. 20 missing parts.
Coal Size/Type: Anthracite. Stove and nut size.
Other Heating: Oil hot water.

Post by DePippo79 » Thu. Oct. 23, 2014 12:56 pm

There's nothing wrong with the stucco/parging job in the attic. Alot of people do that because it's easier than tuck pointing and pretty much hidden from sight. Have the chimney tuck pointed from the roofline up for aesthetics. Good luck. Matt


 
franco b
Site Moderator
Posts: 11417
Joined: Wed. Nov. 05, 2008 5:11 pm
Location: Kent CT
Hand Fed Coal Stove: V ermont Castings 2310, Franco Belge 262
Baseburners & Antiques: Glenwood Modern Oak 114
Coal Size/Type: nut and pea

Post by franco b » Thu. Oct. 23, 2014 1:01 pm

scalabro wrote:
franco b wrote:A warranty is only as good as who stands behind it and does it cover both parts and labor?

Type 316 stainless is best for coal and smooth wall is to be much preferred over a corrugated type which tends to hold fly ash in those corrugations.

Now is the time while it is being installed to think about ease of cleaning.
I wish folks would stop posting that.

AL29 is FAR more corrosion resistant than 316.

Especially at the low exhaust temps of a Herald BB.
I meant as opposed to 304. Now I know better thanks to you. But is the AL29 readily available?

 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Thu. Oct. 23, 2014 1:04 pm

franco b wrote:I meant as opposed to 304. Now I know better thanks to you. But is the AL29 readily available?
It's a mere credit card and mouse click away.

 
coalder
Member
Posts: 1501
Joined: Mon. Dec. 16, 2013 1:48 pm
Location: somewhere high in the catskill mountains
Hand Fed Coal Boiler: harman sf 160
Coal Size/Type: Nut
Other Heating: wood parlor stove

Post by coalder » Thu. Oct. 23, 2014 1:05 pm

Unc, if those guys are still there see if you can give them your camera and take pix of chimney cap & flashing. It really looks like you still have a water problem as dark shaded areas in attic on chimney indicate a problem.
Jim

 
franco b
Site Moderator
Posts: 11417
Joined: Wed. Nov. 05, 2008 5:11 pm
Location: Kent CT
Hand Fed Coal Stove: V ermont Castings 2310, Franco Belge 262
Baseburners & Antiques: Glenwood Modern Oak 114
Coal Size/Type: nut and pea

Post by franco b » Thu. Oct. 23, 2014 1:09 pm

Those dark areas look to me like somebody's effort to re-point.

 
User avatar
wsherrick
Member
Posts: 3744
Joined: Wed. Jun. 18, 2008 6:04 am
Location: High In The Poconos
Hand Fed Coal Stove: Glenwood Base Heater, Crawford Base Heater
Baseburners & Antiques: Crawford Base Heater, Glenwood, Stanley Argand
Coal Size/Type: Chestnut, Stove Size

Post by wsherrick » Thu. Oct. 23, 2014 1:11 pm

J F Graham wrote:Unc, if those guys are still there see if you can give them your camera and take pix of chimney cap & flashing. It really looks like you still have a water problem as dark shaded areas in attic on chimney indicate a problem.
Jim
I think you are right. It looks like he has a roof leak right there. Maybe it's a good thing we all been up in the attic.
And I see absolutely nothing wrong with that chimney. The parging makes me feel even better about it.
Maybe NEPA needs a highly trained stove installation assault team to swoop in and save the day when necessary.

 
coalder
Member
Posts: 1501
Joined: Mon. Dec. 16, 2013 1:48 pm
Location: somewhere high in the catskill mountains
Hand Fed Coal Boiler: harman sf 160
Coal Size/Type: Nut
Other Heating: wood parlor stove

Post by coalder » Thu. Oct. 23, 2014 1:16 pm

My son is a Blackhawk pilot. Think the Army would mind NEPA on the side of it. :D


 
User avatar
Sunny Boy
Member
Posts: 25707
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Thu. Oct. 23, 2014 1:18 pm

franco b wrote:Those dark areas look to me like somebody's effort to re-point.
Agree. The bathroom area of the chimney looks like a homeowner tried to do a quick patching over old mortar instead of a proper job of repointing.

Paul

 
scalabro
Member
Posts: 4197
Joined: Wed. Oct. 03, 2012 9:53 am
Location: Western Massachusetts
Baseburners & Antiques: Crawford 40, PP Stewart No. 14, Abendroth Bros "Record 40"
Coal Size/Type: Stove / Anthracite.
Other Heating: Oil fired, forced hot air.

Post by scalabro » Thu. Oct. 23, 2014 1:20 pm

We have not yet heard if there is a thimble behind the wood trim or plaster/Sheetrock above the mantle.....I hope there is one hidden.

Fingers crossed.

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Thu. Oct. 23, 2014 1:23 pm

wsherrick wrote:
J F Graham wrote:Unc, if those guys are still there see if you can give them your camera and take pix of chimney cap & flashing. It really looks like you still have a water problem as dark shaded areas in attic on chimney indicate a problem.
Jim
I think you are right. It looks like he has a roof leak right there. Maybe it's a good thing we all been up in the attic.
And I see absolutely nothing wrong with that chimney. The parging makes me feel even better about it.
Maybe NEPA needs a highly trained stove installation assault team to swoop in and save the day when necessary.
^^ I agree, nothing wrong with it. It may not be the prettiest repair/patch job ever done but I can't see any reason to not use it.

 
User avatar
Sunny Boy
Member
Posts: 25707
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Thu. Oct. 23, 2014 1:25 pm

J F Graham wrote:My son is a Blackhawk pilot. Think the Army would mind NEPA on the side of it. :D
People may think it's some new government spy agency.

I can see that starting another conspiracy thread. The Army's doing chem trails with fly ash. :D

Paul

 
coalder
Member
Posts: 1501
Joined: Mon. Dec. 16, 2013 1:48 pm
Location: somewhere high in the catskill mountains
Hand Fed Coal Boiler: harman sf 160
Coal Size/Type: Nut
Other Heating: wood parlor stove

Post by coalder » Thu. Oct. 23, 2014 1:32 pm

Paul, you're killing me!!!! :D

 
User avatar
Sunny Boy
Member
Posts: 25707
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Thu. Oct. 23, 2014 1:34 pm

scalabro wrote:We have not yet heard if there is a thimble behind the wood trim or plaster/Sheetrock above the mantle.....I hope there is one hidden.

Fingers crossed.
Wouldn't that be a good bit of news, that Uncle sure could use about now !!!!

Paul

 
User avatar
Sunny Boy
Member
Posts: 25707
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Thu. Oct. 23, 2014 1:38 pm

J F Graham wrote:Paul, you're killing me!!!! :D
Seriously though, please give your son a thank you from me for his service. You must be incredibly proud.

Paul

 
User avatar
D-frost
Member
Posts: 1186
Joined: Sun. Dec. 08, 2013 7:10 am
Location: Southern New Hampshire
Hand Fed Coal Stove: Harman MK ll
Hand Fed Coal Furnace: Yukon Eagle I (multi-fuel oil, wood/coal)
Baseburners & Antiques: Herald 'fireside oak'
Coal Size/Type: nut/stove-Blaschak/Lehigh

Post by D-frost » Thu. Oct. 23, 2014 1:39 pm

I bet NSA has a drone for that pic! Uncle, before I put a SS liner in there, I'd price a poured clay liner( I think it's called terracote), but only if you feel what you have is unsafe. I'm hoping there is a thimble above the damper, that would be good for a trial burn.
What chimney is the furnace connected to? And, I'm counting red brick in the pic- what are the outside dimensions of the chimney? Will it support a 6" liner???(It looks kinda tight from my house)


Post Reply

Return to “Antiques, Baseburners, Kitchen Stoves, Restorations & Modern Reproductions”