Just Ordered a Herald

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Sat. Mar. 28, 2015 5:13 pm

I didn't have any crazy draft readings when it wasn't windy so I'm not sure if it's going to have tamed it or not. I hope it will. right now it's running 200 on the barrel both primaries cracked 1/16" one mpd fully closed and mano is at -.02


 
User avatar
Lightning
Site Moderator
Posts: 14658
Joined: Wed. Nov. 16, 2011 9:51 am
Location: Olean, NY
Stoker Coal Boiler: Modified AA 130
Coal Size/Type: Pea Size - Anthracite

Post by Lightning » Sat. Mar. 28, 2015 5:18 pm

northernmainecoal wrote:I'm afraid at this point it won't be until next season before we really know the results.
Right.. Running it full bore, while it's cold out to boot, and windy on top of that, will have a dramatic different outcome on mano readings.. :)

 
KingCoal
Member
Posts: 4837
Joined: Wed. Apr. 03, 2013 1:24 pm
Location: Elkhart county, IN.
Hand Fed Coal Stove: 1 comforter stove works all iron coal box stove, seventies.
Baseburners & Antiques: 2014 DTS C17 Base Burner, GW #6, GW 113 formerly Sir Williams, maybe others at Pauliewog’s I’ve forgotten about
Coal Size/Type: Nut Anth.
Other Heating: none

Post by KingCoal » Sat. Mar. 28, 2015 5:32 pm

i'll be very surprised if he doesn't still have the same atomic leaf vac above the MPD's

But, if the stove is considerably tighter now, the MPD's will have just as much more ability to limit the neg. pressure on the stove.

Rob, is your weather so seriously abated that you don't see running the stove in the 300's again this yr ?

steve

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Sat. Mar. 28, 2015 5:48 pm

KingCoal wrote:i'll be very surprised if he doesn't still have the same atomic leaf vac above the MPD's

But, if the stove is considerably tighter now, the MPD's will have just as much more ability to limit the neg. pressure on the stove.

Rob, is your weather so seriously abated that you don't see running the stove in the 300's again this yr ?

steve
I hope it is, but who knows. Going to be 8* tonight and after that in the mid 30s daytime and high teens for the low this coming week.

Like you, I'm only expecting to only see a marginal improvement in the atomic leaf vac from this fix but if I'm wrong ill be happy. Id prefer to have to wait until next winter to find out for sure but the way the weather has been this year that may not happen

 
User avatar
Sunny Boy
Member
Posts: 25547
Joined: Mon. Nov. 11, 2013 1:40 pm
Location: Central NY
Hand Fed Coal Boiler: Anthracite Industrial, domestic hot water heater
Baseburners & Antiques: Glenwood range 208, # 6 base heater, 2 Modern Oak 118.
Coal Size/Type: Nuts !
Other Heating: Oil &electric plenum furnace

Post by Sunny Boy » Sat. Mar. 28, 2015 5:57 pm

Those are perfect temps to see what affect sealing air leaks before the grates has on your previous numbers.

Paul

 
KingCoal
Member
Posts: 4837
Joined: Wed. Apr. 03, 2013 1:24 pm
Location: Elkhart county, IN.
Hand Fed Coal Stove: 1 comforter stove works all iron coal box stove, seventies.
Baseburners & Antiques: 2014 DTS C17 Base Burner, GW #6, GW 113 formerly Sir Williams, maybe others at Pauliewog’s I’ve forgotten about
Coal Size/Type: Nut Anth.
Other Heating: none

Post by KingCoal » Sat. Mar. 28, 2015 6:03 pm

the physics of your chimney are set, there will always be exceptional natural draft and frankly that's a good thing, plenty of people wish they had more to work with.

the real story has always been how much it can be controlled and how consistent you can hold the neg. pressure the stove experiences during the most adverse conditions.

that's why closing up both the lower and upper leaks really is important. when you have a stove that is tight everywhere but the adjustable intake ports and you close the MPD's against chimney over draft the stove draft will hold down in the economy range, like it is now.

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Sat. Mar. 28, 2015 6:29 pm

Sunny Boy wrote:Those are perfect temps to see what affect sealing air leaks before the grates has on your previous numbers.

Paul
what numbers would you like to know? what do you think is the best way to show the effect given the currrent conditions?
KingCoal wrote:the physics of your chimney are set, there will always be exceptional natural draft and frankly that's a good thing, plenty of people wish they had more to work with.

the real story has always been how much it can be controlled and how consistent you can hold the neg. pressure the stove experiences during the most adverse conditions.

that's why closing up both the lower and upper leaks really is important. when you have a stove that is tight everywhere but the adjustable intake ports and you close the MPD's against chimney
over draft the stove draft will hold down in the economy range, like it is now.
I agree with you 100% being completely air tight is very important and crucial to the efficiency of the stove. I'm afraid, as I suspect you are, no matter how tight the stove is I won't have the kind of control over the draft I need in extreme conditions. Might as well put it through the paces in this mild weather and wait and see what happens when things get shitty again next year


 
KingCoal
Member
Posts: 4837
Joined: Wed. Apr. 03, 2013 1:24 pm
Location: Elkhart county, IN.
Hand Fed Coal Stove: 1 comforter stove works all iron coal box stove, seventies.
Baseburners & Antiques: 2014 DTS C17 Base Burner, GW #6, GW 113 formerly Sir Williams, maybe others at Pauliewog’s I’ve forgotten about
Coal Size/Type: Nut Anth.
Other Heating: none

Post by KingCoal » Sat. Mar. 28, 2015 6:47 pm

northernmainecoal wrote:
I agree with you 100% being completely air tight is very important and crucial to the efficiency of the stove. I'm afraid, as I suspect you are, no matter how tight the stove is I won't have the kind of control over the draft I need in extreme conditions. Might as well put it through the paces in this mild weather and wait and see what happens when things get shitty again next year
i myself am very confident that you WILL have the control you are hoping for.

it's the soda straw or garden hose illustration. take a straw and apply suction, it'll pass a considerable amount of free air. now, pinch the bottom of the straw, you can pull on that thing till your chest caves in, only so much air is going to come past the obstruction.

in your case you will have obstructions to use both in the smoke pipe and with the adjustable air ports.

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Fri. Apr. 03, 2015 9:33 am

rob, Any plan to add the lacking radiation that is missing from the EFM 520 boiler system?

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Fri. Apr. 03, 2015 10:04 am

McGiever wrote:rob, Any plan to add the lacking radiation that is missing from the EFM 520 boiler system?
Nothing immediate but I do plan on it. I’ve been searching for some old radiators but have missed out on any that I have found thus far. Eventually I’ll find the right deal and start that project. In addition to the radiators I also plan to add in some more fin tube where they just ran pipe behind the baseboard covers

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Thu. Oct. 29, 2015 4:00 pm

It's been a busy summer/fall, didn't get as much done as I would have liked. Started a new job a couple months ago and have even less time now.

I do believe I have all of the underfire leaks sealed up, there was a pretty big gap along the bottom of the ash pan door that is now closed up. Any remaining air gaps are above the fire. I moved the MPD that was closest to the chimney thimble as close to the stove as I could get it. Now I'm trying to decide if I should replace the MPD I moved or stick with two and see how the change in location effects the draft.

Attachments

IMG_20151028_173414657.jpg
.JPG | 100.4KB | IMG_20151028_173414657.jpg
IMG_20151028_171215249.jpg
.JPG | 62KB | IMG_20151028_171215249.jpg

 
User avatar
UncleDoDat
Member
Posts: 263
Joined: Sat. Jun. 21, 2014 11:40 am
Location: Dover De
Hand Fed Coal Stove: King-O-Heat
Baseburners & Antiques: Herald #6
Coal Size/Type: Nut & Stove Size
Other Heating: Natural Gas

Post by UncleDoDat » Fri. Nov. 06, 2015 3:17 am

northernmainecoal wrote:It's been a busy summer/fall, didn't get as much done as I would have liked. Started a new job a couple months ago and have even less time now.

I do believe I have all of the underfire leaks sealed up, there was a pretty big gap along the bottom of the ash pan door that is now closed up. Any remaining air gaps are above the fire. I moved the MPD that was closest to the chimney thimble as close to the stove as I could get it. Now I'm trying to decide if I should replace the MPD I moved or stick with two and see how the change in location effects the draft.
curious to know how a man-o-meter with work inside a double MPD. Furthermore where would you put it with the man-o-meter?

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Wed. Nov. 11, 2015 7:33 am

The mano is placed closest to the stove and then all the MPDs are placed after that. I will be adding in a third MPD, while it wasn't that cold over last weekend it was windy and even with both MPDs fully closed I wasn't able to keep the draft at a reasonable number :/

Attachments

image.jpeg
.JPEG | 112.4KB | image.jpeg

 
coalnewbie
Member
Posts: 8601
Joined: Sat. May. 24, 2008 4:26 pm
Location: Chester, NY
Hot Air Coal Stoker Stove: LL AnthraKing 180K, Pocono110K,KStokr 90K, DVC
Hand Fed Coal Stove: Invader 2
Baseburners & Antiques: Wings Best, Glenwood #8(x2) Herald 116x
Coal Size/Type: Rice,
Other Heating: Heating Oil CH, Toyotomi OM 22

Post by coalnewbie » Wed. Nov. 11, 2015 7:41 am

I agree with you 100% being completely air tight is very important and crucial to the efficiency of the stove
Not so.

 
User avatar
northernmainecoal
Member
Posts: 555
Joined: Wed. Jan. 22, 2014 8:33 am
Location: Aroostook County, Maine
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Hitzer 30-95
Baseburners & Antiques: Herald Baseheater #6
Coal Size/Type: Rice/Nut/Stove

Post by northernmainecoal » Wed. Nov. 11, 2015 8:48 am

coalnewbie wrote:
I agree with you 100% being completely air tight is very important and crucial to the efficiency of the stove
Not so.
??


Post Reply