AA 260 Wiring
-
- New Member
- Posts: 12
- Joined: Sat. Oct. 12, 2013 7:54 pm
- Location: Ashville Pa
- Stoker Coal Boiler: AA260
on the aa 260 you have two wires going to the motor a blue and white. does it matter witch one goes on witch of the two terminals on the motor. (Marathon B317) also do you have to remove or change any of the wires that are already hook up. have 12/2 stranded going to the motor. thanks
- coaledsweat
- Site Moderator
- Posts: 13767
- Joined: Fri. Oct. 27, 2006 2:05 pm
- Location: Guilford, Connecticut
- Stoker Coal Boiler: Axeman Anderson 260M
- Coal Size/Type: Pea
It's been a while but I'll guess there is a terminal with a white wire. White to white.
- Townsend
- Member
- Posts: 573
- Joined: Tue. Nov. 21, 2006 7:38 pm
- Location: Connecticut
- Hand Fed Coal Stove: Hitzer 50-93 & Harman Mark I
- Coal Size/Type: Pea / Nut
Here is a schematic for hot water if you need it. If you have steam let me know. Like coaledsweat said, should be apparent where neutral is when you open motor. If not post pic.
Attachments
-
- New Member
- Posts: 12
- Joined: Sat. Oct. 12, 2013 7:54 pm
- Location: Ashville Pa
- Stoker Coal Boiler: AA260
Thanks Guys. new motor / new install. White goes to # 2 , have blue on other nut. but when I put power (110) to the blue and white wire at the 4" box on furnace with no belts motor seems to work fine. capacitor kicks in it runs and kicks out when it slows down. Now when I hook up the blower belt it starts slow and the capacitor won't kick in or out ? is 12 gauge stranded ok from 4" box to motor or should it be solid wire? hard to bend solid around in motor. thanks
- McGiever
- Member
- Posts: 10130
- Joined: Sun. May. 02, 2010 11:26 pm
- Location: Junction of PA-OH-WV
- Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
- Hand Fed Coal Boiler: BUCKET A DAY water heater
- Hand Fed Coal Stove: Warm Morning 414A
- Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
- Other Heating: Ground Source Heat Pump and some Solar
# 12 stranded wire is perfect.
If you are dealing w/ a 7-wire motor here is the hook up:
There is more than a blue and a white to deal with.
I'm thinking you would want CCW hook up for LOW Volts (120V)
If you have trouble I can call out what color goes where.
If you are dealing w/ a 7-wire motor here is the hook up:
There is more than a blue and a white to deal with.
I'm thinking you would want CCW hook up for LOW Volts (120V)
If you have trouble I can call out what color goes where.
- coaledsweat
- Site Moderator
- Posts: 13767
- Joined: Fri. Oct. 27, 2006 2:05 pm
- Location: Guilford, Connecticut
- Stoker Coal Boiler: Axeman Anderson 260M
- Coal Size/Type: Pea
I went through this when I changed mine, it isn't the wires. See McGiever's post.Justgarfield wrote:Thanks Guys. new motor / new install. White goes to # 2 , have blue on other nut. but when I put power (110) to the blue and white wire at the 4" box on furnace with no belts motor seems to work fine. capacitor kicks in it runs and kicks out when it slows down. Now when I hook up the blower belt it starts slow and the capacitor won't kick in or out ? is 12 gauge stranded ok from 4" box to motor or should it be solid wire? hard to bend solid around in motor. thanks
-
- New Member
- Posts: 12
- Joined: Sat. Oct. 12, 2013 7:54 pm
- Location: Ashville Pa
- Stoker Coal Boiler: AA260
thanks for all the help. needed to change two of the wires around in the motor. it works as it should.
- coaledsweat
- Site Moderator
- Posts: 13767
- Joined: Fri. Oct. 27, 2006 2:05 pm
- Location: Guilford, Connecticut
- Stoker Coal Boiler: Axeman Anderson 260M
- Coal Size/Type: Pea
If she is in fishnet or lace, please post in flame suit central!Townsend wrote: How about a pic of that 260 for us Axeman guys to see and appreciate?
-
- New Member
- Posts: 12
- Joined: Sat. Oct. 12, 2013 7:54 pm
- Location: Ashville Pa
- Stoker Coal Boiler: AA260
Well up and running for a week now. Will send pic when I figure out how.
- McGiever
- Member
- Posts: 10130
- Joined: Sun. May. 02, 2010 11:26 pm
- Location: Junction of PA-OH-WV
- Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
- Hand Fed Coal Boiler: BUCKET A DAY water heater
- Hand Fed Coal Stove: Warm Morning 414A
- Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
- Other Heating: Ground Source Heat Pump and some Solar
Not a step by step, but some good pointers:Justgarfield wrote:Well up and running for a week now. Will send pic when I figure out how.
Post by Stoker6268 - Place Inline?
-
- New Member
- Posts: 12
- Joined: Sat. Oct. 12, 2013 7:54 pm
- Location: Ashville Pa
- Stoker Coal Boiler: AA260
-
- New Member
- Posts: 12
- Joined: Sat. Oct. 12, 2013 7:54 pm
- Location: Ashville Pa
- Stoker Coal Boiler: AA260
-
- New Member
- Posts: 12
- Joined: Sat. Oct. 12, 2013 7:54 pm
- Location: Ashville Pa
- Stoker Coal Boiler: AA260