Post by NhCoal » Tue. Dec. 02, 2014 12:25 pm

Hi,

I have an AA-220 mostly installed in my house. It works, but under load the carbon monoxide detector going off. I need to find someone to help troubleshoot this problem and to finish up small work on the boiler (two pump returns) and installing a heat exchanger.

The person who did the original work left this at 90-95% done, but I am dead in the water without that last bit finished.

Does anyone know someone near the seacoast of New Hampshire who knows coal boilers?

Thanks,
Peter

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Tue. Dec. 02, 2014 12:34 pm

CO when under load...poor chimney.

 
NhCoal
New Member
Posts: 10
Joined: Thu. Apr. 11, 2013 5:07 pm
Stoker Coal Boiler: AA-220

Post by NhCoal » Tue. Dec. 02, 2014 12:55 pm

How do I test / prove that? Paid $$ to chimney guys to do a new 8" insert.


 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Tue. Dec. 02, 2014 12:59 pm

Manometer will tell the truth.

Search Manometer for enlightenment.

 
User avatar
Rob R.
Site Moderator
Posts: 18004
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Tue. Dec. 02, 2014 1:19 pm

What is the 5-10% that is not yet complete?

 
NhCoal
New Member
Posts: 10
Joined: Thu. Apr. 11, 2013 5:07 pm
Stoker Coal Boiler: AA-220

Post by NhCoal » Tue. Dec. 02, 2014 1:56 pm

Putting two returns to two motors on the boiler (supplies done). Installing a heat exchanger for a pool. Troubleshooting problem with CO and boiler.

Peter


 
User avatar
coaledsweat
Site Moderator
Posts: 13767
Joined: Fri. Oct. 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Post by coaledsweat » Tue. Dec. 02, 2014 3:02 pm

Could use some details on the stovepipe and chimney. Have you tried opening a window? AAs when running can easily pressurize the pipe from that monster blower so seal all the stovepipe joints well. Baro? Try covering it with tinfoil and see what happens.

 
User avatar
Rob R.
Site Moderator
Posts: 18004
Joined: Fri. Dec. 28, 2007 4:26 pm
Location: Chazy, NY
Stoker Coal Boiler: EFM 520
Hand Fed Coal Stove: Chubby Jr

Post by Rob R. » Tue. Dec. 02, 2014 3:16 pm

I think this is a Leisure Line 220. Draft must be properly set, and combustion air may need to be adjusted so the combustion chamber is not pressurized.

 
User avatar
watkinsdr
Member
Posts: 243
Joined: Sat. Mar. 24, 2007 8:14 pm
Location: Kensington, New Hampshire
Stoker Coal Boiler: AHS S260 Boiler

Post by watkinsdr » Tue. Dec. 02, 2014 7:56 pm

Check your PMs.... I'll be glad to help you out.

 
User avatar
coalkirk
Member
Posts: 5185
Joined: Wed. May. 17, 2006 8:12 pm
Location: Forest Hill MD
Stoker Coal Boiler: 1981 EFM DF520 retired
Hand Fed Coal Stove: Jotul 507 on standby
Coal Size/Type: Lehigh anthracite/rice coal

Post by coalkirk » Tue. Dec. 02, 2014 9:20 pm

I hope this works out and they are able to complete the install, fire it up and trouble shoot it. This is how friendships are made. Sharing knowledge.