Post by bksaun » Tue. Feb. 26, 2008 7:14 pm

Have the new MK III all hooked up and ready to go except I can't, for the life of me figure out the fire brick pattern, If I install it the way the book shows I end up with 3 pieces left over.

Any Pics or idea's?

BK

 
User avatar
Cap
Member
Posts: 1603
Joined: Fri. Dec. 02, 2005 10:36 pm
Location: Lehigh Twp, PA
Hand Fed Coal Stove: Harman SF 250, domestic hot water loop, heat accumulator
Coal Size/Type: Nut and Stove
Other Heating: Heat Pumps

Post by Cap » Tue. Feb. 26, 2008 7:23 pm

Bricks stand upright across sides and back. Lay sideways across front under door. You may have to break one in half. Sounds like you have 3 extra bricks?


 
titleist1
Member
Posts: 5226
Joined: Wed. Nov. 14, 2007 4:06 pm

Post by titleist1 » Wed. Feb. 27, 2008 10:27 am

As stated, sides and back stand tall, there are two small thin ones that go in the front corners on the side and the front two are sideways with a short skinny one in the middle as a spacer.

 
bksaun
Member
Posts: 1037
Joined: Sat. Oct. 28, 2006 9:24 am
Location: Hustonville, Ky
Hand Fed Coal Boiler: Legacy SF-270
Hand Fed Coal Stove: Hitzer 503
Coal Size/Type: Stoker/Bit, Pea or Nut Anthracite

Post by bksaun » Wed. Feb. 27, 2008 11:15 am

Got it, thanks.