AA260 Auger Screw Size for Inside Transfer Head?

Post Reply
 
User avatar
Vampiro
Member
Posts: 211
Joined: Tue. Feb. 07, 2012 11:10 pm
Location: Transylvania
Stoker Coal Boiler: Axeman Anderson S260
Hand Fed Coal Boiler: #45 BAD HWH
Hand Fed Coal Stove: Harman Mk1
Coal Size/Type: Anthracite, Pea Coal
Other Heating: POS gas boiler

Post by Vampiro » Sat. Feb. 07, 2015 12:49 pm

Hi,

Does anyone know the exact size of the screws that go into the interior gasket ring on the AA 260 Auger head? If these screws do not fit, what is the maximum length screw that can be put in there? Thanks.

 
Mikeeg02
Member
Posts: 244
Joined: Sat. Mar. 09, 2013 7:28 am
Location: Milroy, PA
Stoker Coal Boiler: Axeman Anderson 130
Hot Air Coal Stoker Stove: Old Alaska Kodiak Stoker II
Coal Size/Type: Rice/Pea

Post by Mikeeg02 » Mon. Feb. 09, 2015 8:40 am

Manual says 10-24 x 3/4. On mine they were the same as the screws that hold the split brass bearing between the transfer head and auger tube. I couldn't find the box of screws I bought to find out for sure mine were 10-24, but you could take one out of the brass bearing to find out for sure. I think they could be longer without issue, though the longer they are the more threads are exposed passed what the screw threads into, leaving them to be damaged and possibly harder to remove down the road. I used torx heads myself. Flat heads can be tough to remove down the road, but not as badly as phillips. And I've always had bad luck with allen heads. So torx it was!


 
User avatar
whistlenut
Member
Posts: 3548
Joined: Sat. Mar. 17, 2007 6:29 pm
Location: Central NH, Concord area
Stoker Coal Boiler: AA130's,260's, AHS130&260's,EFM900,GJ & V-Wert
Hand Fed Coal Boiler: Franks,Itasca 415,Jensen, NYer 130,Van Wert
Hot Air Coal Stoker Furnace: Alaska, EFM, Keystoker, Yellow Flame
Hot Air Coal Stoker Stove: Alaska, Keystoker-2,Leisure Line
Hand Fed Coal Stove: Alaska, Gibraltar, Keystone,Vc Vigilant 2
Hand Fed Coal Furnace: Ford, Jensen, NYer, Van Wert,
Baseburners & Antiques: Glenwoods
Coal Size/Type: Barley, Buck, Rice ,Nut, Stove
Other Heating: Oil HWBB

Post by whistlenut » Mon. Feb. 09, 2015 10:58 am

Replace all of them with 10/24 by 3/4" torx screws.......trash the originals........dip a little anti seize on them just for kicks..... Mike knows of what he speaks........

 
User avatar
Vampiro
Member
Posts: 211
Joined: Tue. Feb. 07, 2012 11:10 pm
Location: Transylvania
Stoker Coal Boiler: Axeman Anderson S260
Hand Fed Coal Boiler: #45 BAD HWH
Hand Fed Coal Stove: Harman Mk1
Coal Size/Type: Anthracite, Pea Coal
Other Heating: POS gas boiler

Post by Vampiro » Tue. Feb. 10, 2015 5:57 pm

Thanks guys, will be picking them up tomorrow.