Stove Turning Off

 
miracleon06
Member
Posts: 28
Joined: Fri. Jul. 11, 2008 10:38 am

Post by miracleon06 » Thu. Mar. 19, 2015 11:30 am

Hey guys, I have had an Alaska Channing III since the fall of 2008. Once every so often some ash will build up on a sensor that's inside the stove and shut the stove off. All I usually do to fix it is vacuum out the sensor and lite her back up. This happened the other day so I did what I would normally do. Several hours later the stove was off again. Yesterday I went out and bought a can of spray that you would use to clean the keyboard of your computer and blew out the sensor real good. Five hours later it was out again. This morning when I got home I pulled the direct vent off the side of the house and cleaned that, it definitely needed it, and I also blew the sensor out again, lit it and had a real good fire and then went up stairs to bed. Less then two hours later, the stove is off. Have any of you had this problem before? If so, how did you fix it. Thanks for reading and giving me any feedback you may have.


 
User avatar
coaledsweat
Site Moderator
Posts: 13768
Joined: Fri. Oct. 27, 2006 2:05 pm
Location: Guilford, Connecticut
Stoker Coal Boiler: Axeman Anderson 260M
Coal Size/Type: Pea

Post by coaledsweat » Thu. Mar. 19, 2015 3:46 pm

Have you cleaned your stovepipe? A buildup of ash in there may be causing some effect on the sensor due to reduced draft.

 
User avatar
davidmcbeth3
Member
Posts: 8505
Joined: Sun. Jun. 14, 2009 2:31 pm
Coal Size/Type: nut/pea/anthra

Post by davidmcbeth3 » Thu. Mar. 19, 2015 3:51 pm

Sounds like some safety device ... like garage doors with their electronic eyes?

You know what we do with those LOL.

Can do same thing in this case?

 
User avatar
StokerDon
Site Moderator
Posts: 7502
Joined: Mon. Nov. 11, 2013 11:17 am
Location: PA, Southern York County!
Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood

Post by StokerDon » Thu. Mar. 19, 2015 7:26 pm

davidmcbeth3 wrote:Sounds like some safety device ... like garage doors with their electronic eyes?

You know what we do with those LOL.

Can do same thing in this case?
Not a good idea with a power vent. That thing is the fume switch. It's purpose is to shut down the burner if there is a back up of CO into the stove, thus protecting you from carbon monoxide posining.

One of two things are happening;

1) CO is backing up into the stove. You need a manometer to check your draft to see this.

2) the fume switch is bad. Replace the fume switch.

-Don

 
miracleon06
Member
Posts: 28
Joined: Fri. Jul. 11, 2008 10:38 am

Post by miracleon06 » Fri. Mar. 20, 2015 3:26 am

Hey guys, thanks for the replies. I spent a while tonight cleaning out the stove again. I got my arm up the pipe as far as it would fit and got a brush in it as far as that would fit. I finally managed to find one spot where there was still some ash that seemed to be blocking the draft. I cleaned it out the best I could and reassembled the stove and fired her back up at around 6:30. I had to work tonight, but talked to my wife at around midnight, and she said the stove was still running. Hopefully that means everything is okay. I guess the thing to learn from this, is that ash can get just about anywhere, including where you can't reach very well. Anyways, thanks for the feedback and let's hope it continues to run.

 
User avatar
freetown fred
Member
Posts: 30302
Joined: Thu. Dec. 31, 2009 12:33 pm
Location: Freetown,NY 13803
Hand Fed Coal Stove: HITZER 50-93
Coal Size/Type: BLASCHAK Nut

Post by freetown fred » Fri. Mar. 20, 2015 5:49 am

Nice M. Keep us posted.

 
titleist1
Member
Posts: 5226
Joined: Wed. Nov. 14, 2007 4:06 pm

Post by titleist1 » Fri. Mar. 20, 2015 7:17 am

Could you post a pic of your flue pipe? We might have a suggestion or two on how to make it easier to clean more frequently.


 
User avatar
StokerDon
Site Moderator
Posts: 7502
Joined: Mon. Nov. 11, 2013 11:17 am
Location: PA, Southern York County!
Stoker Coal Boiler: Gentleman Janitor GJ-5, Van Wert VA-600, Axeman Anderson130 X3.
Hand Fed Coal Furnace: Harman SF3500 reduced down to 3 grates connected to its own plenum
Coal Size/Type: Rice, Chestnut and whatever will fit through the door on the Harman
Other Heating: Noth'in but COAL! Well, Maybe a little tiny bit of wood

Post by StokerDon » Fri. Mar. 20, 2015 5:27 pm

miracleon06 wrote:Hey guys, thanks for the replies. I spent a while tonight cleaning out the stove again. I got my arm up the pipe as far as it would fit and got a brush in it as far as that would fit. I finally managed to find one spot where there was still some ash that seemed to be blocking the draft. I cleaned it out the best I could and reassembled the stove and fired her back up at around 6:30. I had to work tonight, but talked to my wife at around midnight, and she said the stove was still running. Hopefully that means everything is okay. I guess the thing to learn from this, is that ash can get just about anywhere, including where you can't reach very well. Anyways, thanks for the feedback and let's hope it continues to run.
Thats' great news. This means CO was backing down into the stove tripping the fume switch. Removing the blockage has likely restored your draft to normal.

I hope you have CO detectors!!!

-Don

 
User avatar
blrman07
Member
Posts: 2383
Joined: Mon. Sep. 27, 2010 3:39 pm
Location: Tupelo Mississippi

Post by blrman07 » Fri. Mar. 20, 2015 8:33 pm

Very easy description by Matthaus on how a fume switch works posted about 6 1/2 years ago.

Re: CO / Fume switch - How does it work??
PostBy: Matthaus On: Sun Oct 26, 2008 8:44 pm

The WMO-1 Safety switch works by keeping cool when a negative pressure inside the firebox draws air through the tube and into the stove, thus keeping the snap disc cool. if the DV or PV stops the heat will exit through the tube and trip the snap disc.

I always test the stoves I sell with a WMO-1 by shutting off the vent and waiting for it to trip, usually takes a minute or two. remember it is a manual reset, so you will have to depress the red button before the stove will work again.

Hope this provides some data in your quest for comfort. :)
Matthaus

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Fri. Mar. 20, 2015 9:25 pm

davidmcbeth3 wrote:Sounds like some safety device ... like garage doors with their electronic eyes?

You know what we do with those LOL.

Can do same thing in this case?
Please refrain from giving out life threatening suggestion on this public board. :no1: :wtf:

Wouldn't want someone to be harmed or die from taking things out of context.

 
User avatar
davidmcbeth3
Member
Posts: 8505
Joined: Sun. Jun. 14, 2009 2:31 pm
Coal Size/Type: nut/pea/anthra

Post by davidmcbeth3 » Fri. Mar. 20, 2015 10:54 pm

McGiever wrote:
davidmcbeth3 wrote:Sounds like some safety device ... like garage doors with their electronic eyes?

You know what we do with those LOL.

Can do same thing in this case?
Please refrain from giving out life threatening suggestion on this public board. :no1: :wtf:

Wouldn't want someone to be harmed or die from taking things out of context.
Sorry I could not reply sooner, I was stuck under my garage. I thought it was a useless electric eye....my bad.

 
User avatar
mariohotshot
Member
Posts: 114
Joined: Sun. Oct. 27, 2013 10:58 pm
Location: Blakeslee, PA

Post by mariohotshot » Sat. Mar. 21, 2015 6:46 am

It's important to know that safety devices are NOT useless.
They are meant to protect equipment and people from damage and injuries or death! :shock:

.[/quote]Sorry I could not reply sooner, I was stuck under my garage. I thought it was a useless electric eye....my bad.[/quote]

 
User avatar
McGiever
Member
Posts: 10130
Joined: Sun. May. 02, 2010 11:26 pm
Location: Junction of PA-OH-WV
Stoker Coal Boiler: AXEMAN-ANDERSON 130 "1959"
Hand Fed Coal Boiler: BUCKET A DAY water heater
Hand Fed Coal Stove: Warm Morning 414A
Coal Size/Type: PEA,NUT,STOVE /ANTHRACITE
Other Heating: Ground Source Heat Pump and some Solar

Post by McGiever » Sat. Mar. 21, 2015 11:45 am

Getting a toe pinched is not the same as coming home and finding ones family dead of Carbon Monoxide Poisoning because a Safety was "jumpered out". :sick:

 
CotyRedeye
New Member
Posts: 3
Joined: Sun. Dec. 25, 2022 1:08 pm
Coal Size/Type: Model 140 dual

Post by CotyRedeye » Sat. Mar. 23, 2024 12:11 am

I have a Alaska model 140 dual stoker stove although I only use one side, the stove just completely shut off, will not power back on and I’m not sure what the problem is. For a couple days it seems as if the coal is just burning and it’s not kicking ok the fan to blow the heat it’s been 60 in the house.

 
Hootyburra
Member
Posts: 159
Joined: Sun. Sep. 17, 2017 8:43 pm
Hot Air Coal Stoker Stove: Alaskan Stoker II
Coal Size/Type: Rice
Other Heating: Oil

Post by Hootyburra » Sat. Mar. 23, 2024 7:54 am

CotyRedeye wrote:
Sat. Mar. 23, 2024 12:11 am
I have a Alaska model 140 dual stoker stove although I only use one side, the stove just completely shut off, will not power back on and I’m not sure what the problem is. For a couple days it seems as if the coal is just burning and it’s not kicking ok the fan to blow the heat it’s been 60 in the house.
I'm sure some photos would be extremely helpful in troubleshooting.
Have you checked voltage is good for the power coming to the stove?
Have your tried plugging and of the motors direct to a wall outlet to see if they work?


Post Reply