Stove suddenly stopped working

Stove suddenly stopped working

PostBy: tahoe On: Tue Mar 04, 2008 8:18 pm

We own an Alaska Channing III which is directly vented because we do not have a chimney. this evening the whole motor/blower stopped running. We checked the power supply and it was not that. Does anyone have any idea why it would just quit?
tahoe
 
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing

Re: Stove suddenly stopped working

PostBy: Devil505 On: Tue Mar 04, 2008 8:41 pm

Is it getting power? Is there a reset button? (If not, it's your blower motor)
Last edited by Devil505 on Tue Mar 04, 2008 8:43 pm, edited 1 time in total.
Devil505
 
Stove/Furnace Make: Harman
Stove/Furnace Model: TLC-2000

Re: Stove suddenly stopped working

PostBy: tahoe On: Tue Mar 04, 2008 8:43 pm

yes, we checked the outlet and there is power.
tahoe
 
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing

Visit Lehigh Anthracite

Re: Stove suddenly stopped working

PostBy: Jerry & Karen On: Tue Mar 04, 2008 8:43 pm

Tahoe,
Check your WMO-1 safety switch. If your pipes are dirty or your venter hasn't been cleaned it awhile, then that's the problem.
Jerry
Jerry & Karen
 

Re: Stove suddenly stopped working

PostBy: tahoe On: Tue Mar 04, 2008 8:58 pm

Just checked the WMO-1 switch, we seem to have power now. Thanks for suggesting it. We'll see if it keeps running.
tahoe
 
Stove/Furnace Make: Alaska
Stove/Furnace Model: Channing

Re: Stove suddenly stopped working

PostBy: LsFarm On: Tue Mar 04, 2008 9:19 pm

Have you cleaned the direct vent fan/motor assembly and the flue/exhaust pipe lately??? When these get clogged with flyash, then the WMO-1 switch will open and shut the stove down to prevent Carbon Monoxide from being forced into the living space..

Greg L
.
LsFarm
 
Stoker Coal Boiler: Axeman Anderson 260
Hand Fed Coal Boiler: Self-built 'Big Bertha' SS Boiler
Baseburners & Antiques: Keystone 11, Art Garland